Hotel Lock
Lock Body: Zinc Alloy Material. Mortise: ANSI Standard, 5 latch mortise. Finish: Polished Gold/Polished Chrome/Satin ChromeOutside Handle: Free rotate in locked state to protect lock structure from malicious destroy. Cylinder: Equipped for mechanical key unlocking. Installation Thickness: 35 - 55 mm door thickness required. Power: 6V, 4 AA Alkaline Batteries. Normally 10000 unlocking. Low power warning: < 4.8V, 200 unlocking permitted. Key Card: Mifare 1 contactless cardUnlocking Records: 1000 pcs. Action time: 1 turning of handle permitted after successful reading cards, then return to lock state. If no turning of handle after card reading, return to lock state in 7 seconds. Static Consumption: < 5 uA Dynamic Consumption: < 200mA
Lock Body: Zinc Alloy Material. Mortise: ANSI Standard, 5 latch mortise. Finish: Polished Gold/Polished Chrome/Satin ChromeOutside Handle: Free rotate in locked state to protect lock structure from malicious destroy. Cylinder: Equipped for mechanical key unlocking. Installation Thickness: 35 - 55 mm door thickness required. Power: 6V, 4 AA Alkaline Batteries. Normally 10000 unlocking. Low power warning: < 4.8V, 200 unlocking permitted. Key Card: Mifare 1 contactless cardUnlocking Records: 1000 pcs. Action time: 1 turning of handle permitted after successful reading cards, then return to lock state. If no turning of handle after card reading, return to lock state in 7 seconds. Static Consumption: < 5 uA Dynamic Consumption: < 200mA
Hotel Lock System Introduction
System:
Confitek intelligent hotel lock system consists of 5 parts: Management software; Door locks; Encoder; Keycards and Staff cards; and Records Reader
Types:
IC card lock system, RF card lock system, Mifare card lock system.
Expanded Functions: For Mifare card, since it has 16 memory sectors, where our lock system only ocupy 2 among them, and left other sectors for other systems, so that Mifare card will be used by other hotel systems.
Software Features:
1: Establish the frame of guest room numbers.
2: Distribute unlocking authority among hotel staff according to their different positions.
3: Easy operation interface menu, no complicated menu structure.
4: Sufficient functions to fulfil most of the hotel running requirement.
5: One keycard for guest to open different rooms.
6: Report of all kinds of system information.
Solution:
1: Install software and door lock
2: connect encoder with software
3: Issue program cards to write system data in cards
3: Read program cards on locks to write system data in lock
4: Issue keycards for guests.
That' s all very easy