Specifications:
Conditions of power supply: Voltage A.C380V/220V±10%
Frequency: 50Hz±1Hz
Capacity: 20KVA
Power supply resistance: A.C380V≤1.0 Ω; A.C220V≤0.03Ω
Maximum tube Voltage: 125KV
Maximum tube current: 200mA
Fluoroscopy: Tube voltage: 40-110KV
Tube current: 0.5-5mA
Radiograph: Tube voltage: 40-125KV
Tube current: small focal spot: 25mA, 50mA,100mA; big focal spot:150mA. 200mA
Spotfilm: 100mA (small focal spot)
High voltage generator: Capacity 15KW
Type of X-ray tube: Model: XD51-20,40/125
Focal spot: Spotsmall focal spot: 1x1mm, big focal spot: 2x2mm
Rotate speed of anode: 2800r/min
Diagnostic table: Scope of rotation: 90°~0°~-5°
Mobile bean filtration device: Grid density: N=28
Focusing distance: fo>10000mm Grid ratio: r=8
Distance from surface to film: ≤60mm
Stomach&intestine radiograph device: Spotfilm device specifications: 127x178mm(5"x7") Binary picture 203254mm(8"x10")Binary picture 254x305mm(10"x12") Binarypicture 280x356mm(11"x14") Binary picture
Moving lengthways (along groud railway) 1500mm
Moving crosswise (left and right) 740mm
Moving up and right: 700-1900mm
Way of down: Electromagnetism locking Beam limited device: Manually single automatic muiti-optional
Table for radiograph: 2000x760x680mm
Movable range of bed facee Vertical: ±450mm Horizontal:± 110mm
Column longitudinal movement: 1000mm
Film from the bed: ≤60mm
Tube moves up and down: 1100mm-1760mm
Radiography with Gird for cassette specifications: 10'x12', 11'x14', 12'x15'
Features:
1, Double diagnostic bed and double X-ray tube.
2, Equipped with KV.mA.S chain protection device, time limited protection device
of radiograph.
3, Equipped with the manostat for filament of X-ray tube and the spacecharge
compensator as to ensure the stable and accurate output. There is no ceiling
track and install conveniently, easy to operate.
4, The sport film device of screen can use various sizes film jakect.
5, Equipped with magnetic lock.
Conditions of power supply: Voltage A.C380V/220V±10%
Frequency: 50Hz±1Hz
Capacity: 20KVA
Power supply resistance: A.C380V≤1.0 Ω; A.C220V≤0.03Ω
Maximum tube Voltage: 125KV
Maximum tube current: 200mA
Fluoroscopy: Tube voltage: 40-110KV
Tube current: 0.5-5mA
Radiograph: Tube voltage: 40-125KV
Tube current: small focal spot: 25mA, 50mA,100mA; big focal spot:150mA. 200mA
Spotfilm: 100mA (small focal spot)
High voltage generator: Capacity 15KW
Type of X-ray tube: Model: XD51-20,40/125
Focal spot: Spotsmall focal spot: 1x1mm, big focal spot: 2x2mm
Rotate speed of anode: 2800r/min
Diagnostic table: Scope of rotation: 90°~0°~-5°
Mobile bean filtration device: Grid density: N=28
Focusing distance: fo>10000mm Grid ratio: r=8
Distance from surface to film: ≤60mm
Stomach&intestine radiograph device: Spotfilm device specifications: 127x178mm(5"x7") Binary picture 203254mm(8"x10")Binary picture 254x305mm(10"x12") Binarypicture 280x356mm(11"x14") Binary picture
Moving lengthways (along groud railway) 1500mm
Moving crosswise (left and right) 740mm
Moving up and right: 700-1900mm
Way of down: Electromagnetism locking Beam limited device: Manually single automatic muiti-optional
Table for radiograph: 2000x760x680mm
Movable range of bed facee Vertical: ±450mm Horizontal:± 110mm
Column longitudinal movement: 1000mm
Film from the bed: ≤60mm
Tube moves up and down: 1100mm-1760mm
Radiography with Gird for cassette specifications: 10'x12', 11'x14', 12'x15'
Features:
1, Double diagnostic bed and double X-ray tube.
2, Equipped with KV.mA.S chain protection device, time limited protection device
of radiograph.
3, Equipped with the manostat for filament of X-ray tube and the spacecharge
compensator as to ensure the stable and accurate output. There is no ceiling
track and install conveniently, easy to operate.
4, The sport film device of screen can use various sizes film jakect.
5, Equipped with magnetic lock.