Product Main

Specifications

Offer aidu AD-3530AA Atomic Absorption Spectrophotometer
element analyzer, ore analyzer, alloy analyzer, portable element analyzer , chemical analysis method,multi-element analyzer,trace element analysis,desktop elemental analyzer,gold content analyzer,atomic absorption analyzer,mine composition analyzer,mine elements analyzer,composition elements analyzer,gold tester etc.

We are one of the largest  professional and reliable  manufacturers of  geophysical prospecting instrument in China,supply various geophysical instrument, resistivity meter, resistivity IP and SP system, resistivity, IP, SP, TEM survey, magnetometer, logging systerm,seismograph, gravity meter, proton magnetometer, water detector,mineral prospector,drilling equipment, logging system and element analyzer etc.

Specifications:
Atomic Absorption Spectrophotometer AD-3530AA Series is a new generation of domestic high level products that it broke the technology bottleneck of D-lamp background correction. And also provided a reliable safeguard for elements quantitative analysis
Character:
Unique full reflection optical system
D-lamp background correction
High resolution and exact peak seeking ability
3 Atomic temperature rise mode
Unique design automatic 8 lamps holder system
Steady flow full titanium burner
Intelligence control function
General safety precautions
Window2000/XP conciseness, professional, automatic, full operation SP Win-AAS software
QA/QC function
Full information measurement
 
Main Parameter:
Optical System
•   Instrument Type Single Beam Reflection Achromatic Optics System
•   Monochrometer: Achromatic C-T
•   Bandwidth(nm): 0.1,0.2,0.7,1.4nm Adjustable
•   Wavelength Range (nm): 190-900
•   Wavelength Accuracy (nm): ± 0.20
•   Wavelength Repeatability(nm): ≤ 0.10
•   Resolution better than 0.3nm (Mn279.5nm and 279.8nm peak valley≤ 30%)
 
Spectrophotometric Properties:
•   Measurement: A. T.C
•   Photometric Range: 0-125%, -0.1-3.00A
•   Static Baseline Drift (Cu): ± 0.003A/30min
•   Dynamic Baseline Drift (Cu): ± 0.004A/30min
•   Background Correction: D-lamp background correction, Self-absorbance background correction > 50times correction ability (1Abs)
•   Atomization System: Flame + graphite furnace
  Flame:
•   Characteristic Concentration: (Cu)≤ 0.03ug/mL/1%
•   Detection limit: (Cu)≤ 0.006ug/mL
•   Precision: RSD≤ 1%
•   Burner: titanium
•   Nebulizer: hight-efficient glass nebulizer
•   Spray chamber: anticorrosion material
•   Safety measures: Flame fuel gas, power assisted gas abnormal pressure protection
Graphite Furnace
•   Characteristic quantity Characteristic value: Cd≤ 0.5× 10-12g
•   Detection Limit Characteristic value: Cd≤ 1.0× 10-12g
•   Precision Precision: Cd≤ 3%
•   Test Manner : Flame, Graphite Furnace, hydride-AA, flame emission
  Data Process
•   Concentration: Standard curve, standard addition, interpolation
•   Times of repetitive Measurement: 1-30times, Average value of A& C
•   QA/QC: relative coefficient, Abs. concentration SD, RSD, Analysis data electronic document export is feasible.
•   data output: Test data could be saved as original record form through Pro-software
•   report print: parameters, data result, graph
•   data interface: Standard RS-232 interface
Instrument function
•   Instrument setup D-lamp background correction auto-adjust optics beam device
•   Automatic wavelength scan, peak seeking band width adjust
•   Automatic ignite adjust negative high voltage
•   lamp current, balance two beams, flameout protection