◆ Universal Input: 100~240VAC 50~60Hz
◆ Protections: Short circuit/ Overload/ Over temperature
◆ O/P: High accuracy, low noise; hold up time≥20mS
◆ Cooling by free air convection; Auto recovery;
◆ Cooling by free air convection; Auto recovery;
◆ Operation temperature: -10℃~+40℃;
◆ 100% full load burn-in test for 8 hours
◆ High Efficiency, high reliability;
◆ 100% full load burn-in test for 8 hours
◆ High Efficiency, high reliability;
◆ Built-in Class B EMI Filter
◆ Long life of 50,000Hours, 2 years warranty
◆ Long life of 50,000Hours, 2 years warranty
◆ Compliance to EN55022 / EN60950 / UL60950
GS CB UL FCC CE ROHS
|
SPECIFICATION
|
|||||||
|
MODEL
|
SRA-5V-48W
|
SRA-12V-48W
|
SRA-24V-48W
|
SRA-36V-48W
|
|||
|
OUTPUT
|
DC VOLTAGE
|
5.0V
|
12V
|
24V
|
36V
|
||
|
RATED CURRENT
|
5.0A
|
4.0A
|
2.0A
|
1.5A
|
|||
|
CURRENT RANGE
|
0~5.0A
|
0~4.0A
|
0~2.0A
|
0~1.5A
|
|||
|
RATED POWER
|
25W
|
48W
|
48W
|
48W
|
|||
|
RIPPLE&NOISE(max)
|
80mVp-p
|
150mVp-p
|
200mVp-p
|
250mVp-p
|
|||
|
LINE REGULATION
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
|||
|
VOLTAGE TOLERANCE
|
± 5%
|
± 5%
|
± 5%
|
± 5%
|
|||
|
SETUP TIME
|
800ms@110VAC; 400ms@230VAC
|
||||||
|
RISE TIME
|
50ms@110VAC/230VAC
|
||||||
|
HOLD UP TIME
|
20ms@230VAC
|
||||||
|
INPUT
|
VOLTAGE RANGE
|
90~264VAC
|
FREQUENCY RANGE
|
47~63Hz
|
|||
|
POWER FACTOR
|
PF>0.68
|
||||||
|
EFFICIENCY (Typ.)
|
76%
|
79%
|
82%
|
82%
|
|||
|
AC CURRENCY
|
1.20A/110VAC, 0.75A/230VAC
|
||||||
|
INRUSH CURRENT (max)
|
COLD START 30A/230VAC
|
||||||
|
LEAKAGE CURRENT(max)
|
0.75mA / 230VAC
|
||||||
|
ENERGY CONSUMPTION
|
The consumption should be less than 0.75 Watt at normal input
|
||||||
|
INPUT PLUG TYPE
|
IEC-C6 / IEC-C8
|
||||||
|
ENVIROMENT
|
WORKING TEMP.
|
-10℃~+40℃
|
|||||
|
WORKING HUMIDITY
|
20%~90% RH non-condensing
|
||||||
|
STORAGE TEMP. HUMIDITY
|
-25℃~+80℃, 10%~95%RH
|
||||||
|
TEMP. COEFFICIENT
|
± 0.05% / ℃ (0~50℃)
|
||||||
|
VIBRATION
|
10~500Hz, 2G 10min./1cycle, period for 60min. each along X,Y,Z axes.
|
||||||
|
OTHERS
|
DIMENSION (mm)
|
110*55*32mm (L*W*H)
|
|||||