Product Main

Specifications

Applications
  • These fuse holders are supporters for fuses with size up to 22x58mm. They are capable of working under heat caused by rated current and expected short impacting current up to 100KA. It can also function as a fuse disconnecting switch by multi-phase combination. There are two in/out lines at the RT18N fuse base, providing a power cut function. The RT18L type has a safety lock to lock the fuse carrier when disconnected to avoid wrong operation; it can also be equipped with an indicator, which goes on when the fuse link breaks.
  • Rated insulate voltage up to 690V; Working frequency 50Hz AC; Conventional free air thermal current up to 125A; Compliant withGB13539.1, GB13539.2, GB13539.6, GB14048.3 and IEC269-1,IEC269-2, IEC269-2-1, IEC947-3 .
Design Features
  • After the plastic-injected case is equipped with contacts and fuse links, the bases are formed by welding or riveting both capable of being multi-phase structured. FB15C, FB16-3J, FB19C-3J, RT19 are open-structure, and others are semi-concealed structure. There are five fuse sizes available to choose from for the same fuse base of RT18N, RT18B and RT18C. There are two sets of in-out lines for RT18N. One is installed with fuse links of the according size. The other is permanent open contacts with double breaking points. The whole base unit can cut the power.RT18 bases are all DIN rail installed, among which the RT18L is equipped with safety lock against wrong operation in the breaking state.
Base Data: 
  •  The models, rated insulate voltage, rated current, and dimensions are shown in Figures 1~14 and Table 1~14 (Width of N-phasecombination is Bn-nB).
Models Fuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)        
        Fig.          
RT14-20 10x38 500 20 Bolt installing hole Φ4.5 Figure 1 38        
RT14G-20 10x38 500 20 Widt 15mm rail installation Figure 1 44        
                   
Models Fuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm)
Fig. A1 B H1 H2 Φd
RT14-32 14x51 500 32 Figure 2 105 26.5 57 135 5.5
RT14-63 22x58 500 63 Figure 2 125 35 66 158 5.5
                   
Models Fuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm)
Fig. A1 B H1 H2 Φd
RT19-16 8.5x31.5 500 16 Figure 3 69 18.5 28.5 41.5 5
RT19-25 10x38 500 25 Figure 3 80 23 35 53 6.5
                   
Models Fuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm) Weight (g)
Fig. A1 B H1 Φd
RT19-40 14x51 500 40 Figure 4 91 28.5 40 5.5 78
RT19-100 22x58 500 100 Figure 4 108 36 50 6.5 157
                   
Models Fuse Link models Rated insulation voltage (V) Conventional free air themal current (A) Dimensions/ Sizes(mm)
Fig. A1 A2 B H1 H2
RT18-32(X) 10x38 500 32 Figure 5 79 81 18 61 80
RT18B-10 8.5x23 500 10 Figure 5 80 82 18 60 78
RT18B-16 10x25.8 500 16 Figure 5 80 82 18 60 78
RT18B-20 8.5x31.5 500 20 Figure 5 80 82 18 60 78
RT18B-25 10x31.5 500 25 Figure 5 80 82 18 60 78
RT18B-32 10x38 500 32 Figure 5 80 82 18 60 78
RT18C-10 8.5x23 500 10 Figure 5 77 78 18 62 81
RT18C-16 10x25.8 500 16 Figure 5 77 78 18 62 81
RT18C-20 8.5x31.5 500 20 Figure 5 77 78 18 62 81
RT18C-25 10x31.5 500 25 Figure 5 77 78 18 62 81
RT18C-32 10x38 500 32 Figure 5 77 78 18 62 81
RT18M-32 10x38 500 32 Figure 5 78 78 18 60 80
HG30-32 10x38 500 32 Figure 5 78 80 18 73 88
RT18-63(X) 14x51 500 63 Figure 5 103 105 27 80 110