Features:
■ Single or Twins Ultrasound transducer
■ Data Graph and Trend Table Review of both mother and fetal
■ Built-in thermal printer
■ Built-in Network capability for connect with central monitoring software
■ Programmable alarms
■ All the colors and looks or the parameters can be customsized
■ Multi-face views, select focus on mother or fetal
■ Storage of patient information and data
Performance Specifications:
■ Display:8.4" Color TFT
■ Resolution:640x480
■ Display Mode:Standard View,Fetal View,Mother View
■ Indicator:Power indicator light, Alarm sound
■ Interface:Socket for connecting fetal's FHR, TOCO, and Fetal Movement sensorSocket for connecting mother's ECG,
NIBP and SPO2 sensor. Net Socket(RJ45) for communication cable with
Central Monitoring Station Sofrware.
Central Monitoring Station Sofrware.
■ Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA
■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
■ Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
■ User Configuration:All the color of parameters and waves can be set according to user's willing.
Technical specifications:
■ Safety
■ Meet the requirment of IEC60601 series
■ Type of Protection:Class II with internal electirc power supply
■ Degree of Protection:BF
■ Dimention and Weight
■ Dimention:92(W)x82(H)x22(D)mm
■ Weight:136g(with battery)
■ Operation Environment:
■ Temperature:0℃~ +40℃
■ Humidity:15% ~ 95%
■ Storage Environment:
■ Temperature:-20℃~ +60℃
■ Humidity:10% ~ 95%
■ Patient Range:Pregnant Adult
■ FHR
■ Ultrasound Frequency:2MHz
■ Range:50 ~ 210 bpm
■ Resolution:1bmp
■ Accuracy:±2bmp
■ TOCO
■ Range:0 ~ 100%
■ Resolution:1%
■ Non-linear Error:<=±8%
■ Zero control:Manual
■ FETAL MOVEMENT
■ Manual fetal movement mark
■ SPO2
■ Measurement Range:0 ~ 100%
■ Resolution:1%
■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
■ Alarm Range:0% ~ 100%
■ Refreshing Rate:1s
■ Pulse Rate
■ Measurement Range:25 ~ 250 bpm
■ Resolution:1bpm
■ Accuracy:±3 bpm (non-motion)
■ Alarm Range:25 ~ 250 bmp
■ Refreshing Rate:1s
■ ECG
■ Lead mode:3-lead or 5-lead
■ Lead selection:I, II, III, AVR, AVL, AVF, V
■ HR range:15 ~ 300 bpm
■ ECG Waveform:2 channals
■ Accuracy:±2bpm or ±2%, which is greater
■ S-T segment detection range: -2.0mv ~ +2.0mv
■ Arrhythmia analysis: 13 kinds of arrhythmia
■ Alarm Range:15 ~ 300 bpm
■ NIBP
■ Method:Oscillometry
■ Mode:Manual/Auto/Contiuous
■ Measurement Range:25 ~ 260mmHg
■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
■ Resolution:1mmHg
■ Overpressure Protection: 300mmHg
■ Alarm range:25 ~260mmHg