Detailed Product Description
power supply circuit 15V/4A
1.Switch power supply witch CE
2.Competitived price,Shortest lead time
3.Sample order is availabl
1.Switch power supply witch CE
2.Competitived price,Shortest lead time
3.Sample order is availabl
power supply circuit 15V/4A,ac/dc adapter,regulated power supply
105°C output capacitor
With short-circuit and overload protection
AC Input Power
100% full-load burn-in test
High efficiency&Low Operation temperture
Installed with EMI filter,minimum wave
|
Model
Performance
|
S-60-5
|
S-60-12
|
S-60-15
|
S-60-24
|
|
DC Output Volta
|
5V
|
12V
|
15V
|
24V
|
|
Output voltage tolerance(Note 2)
|
±2%
|
±1%
|
±1%
|
±1%
|
|
Rated output current
|
12A
|
5A
|
2.8A
|
1.8A
|
|
Output current range
|
0-12A
|
0-5A
|
0-2.8A
|
0-1.8A
|
|
Ripple and noise(Note 3)
|
70mVp-p
|
120mVp-p
|
150mVp-p
|
150mVp-p
|
|
Inlet stability(Note 4)
|
±0.5%
|
±0.5%
|
±0.4%
|
±0.25%
|
|
Load stability(Note 5)
|
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
DC output power
|
60W
|
60W
|
60W
|
60W
|
|
Efficiency
|
73%
|
76%
|
77%
|
79%
|
|
DC voltage adjustable range
|
+10,-5%
|
±10%
|
±10%
|
±10%
|
|
Input voltage range
|
85~264VAC/47~63Hz;120~370VDC
|
|||
|
Input current
|
2A/115V 1A/230V
|
|||
|
Surge Current
|
Cold Start current 30A/115V 60A/230V
|
|||
|
Leakage Current
|
<3.5mA/240VAC
|
|||
|
Overload protection
|
105%~150%type:PULSING HICCUP SHUTDOWN reset:Automatic recovery
|
|||
|
over-voltage protection
|
115%~135%
|
|||
|
High temperature protection
|
……
|
|||
|
temperature coefficient
|
±0.03%°C(0~50°C)
|
|||
|
Start-up,upper,rentention time
|
800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC
|
|||
|
shock resistance
|
10~500Hz,2G 10min./1circle,time:60min.,axes
|
|||
|
Withstand
|
Input to Output Isolation:3KVAC,input shell:1.5KVAC,output shell:0.5KVAC
|
|||
|
Insulation Resistance
|
Input and out shell, output and out shell:500VAC/100M Ohm
|
|||
|
work Temperature/
humidity
|
-10°C~+60°C,20%~90%RH
|
|||
|
Storage Temperature,temperature
|
-20°C~+85°C,10%~95RH
|
|||
|
Outline dimension
|
159*97*38mm
|
|||
|
Weight
|
0.55Kgs
|
|||
|
Safety standards
|
Satisfy UL1012,TUV EN60950
|
|||
|
EMC Standard
|
Satisfy IEC801-2,3,4,IEC555-2
|
|||
|
Note:
1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH.
Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF
capacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the
incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.
6. C2,3,6 must Remove
|
||||