Product Main

Specifications

10KV-35kv  heat shrinkable cable terminaltion and joint
For  PVC.XLPE Rubber-plastic insulated 1-core 2-cores 3-cores 4-cores 5cores power cable heat shrinkable  termination .
 
Feature
1. Preferable electrical appliance function
2. Reliable insulation
3. Superior hermetic sealing
4. Excellent heat /cold proof ,waterproof ,Anti-aging ,
5. widely used at the field of electric power, electronic, petroleum, 
 chemical engineering, construction and communication
 
35kV cable heat shrinkable termination and Sraight through joint
10kv-35kV High-voltage products of cable termination are mainly and universally applied to dealing with disconnection place of Cable below 10kv-35kV. In cable cores, products are classified single core, three cores.etc.

10KV heat shrinkable cable terminaltion and joint
Items
Typical data
AC withstand for 1min
45kv/min
DC negative polarity voltage withstand 
52Kv
Partial discharge 
≤20Pc
Impulse voltage withstand
105kv
AC withstand for 4h
35kv


Indoor termination
Outdoor termination
Straight through joint
size of conductor
(mm2)
Single core
Three cores
Single core
Three cores
Single core
Three cores
NSY-10/1.1
NSY-10/3.1
WSY-10/1.1
WSY-10/3.1
JSY-10/1.1
JSY-10/3.1
25-50
NSY-10/1.2
NSY-10/3.2
WSY-10/1.2
WSY-10/3.2
JSY-10/1.2
JSY-10/3.2
70-120
NSY-10/1.3
NSY-10/3.3
WSY-10/1.3
WSY-10/3.3
JSY-10/1.3
JSY-10/3.3
150-240
NSY-10/1.4
NSY-10/3.4 
WSY-10/1.4 
WSY-10/3.4 
JSY-10/1.4
JSY-10/3.4
300-400 
 
 20KV heat shrinkable cable terminaltion and joint
Items
Typical data
AC withstand for 1min
56kv/min
DC negative polarity voltage withstand 
96Kv
Partial discharge 
≤20Pc
Impulse voltage withstand
125kv
AC withstand for 4h
48kv
Indoor termination
Outdoor termination
Straight through joint
size of conductor
(mm2)
Single core
Three cores
Single core
Three cores
Single core
Three cores
SY-20/1.1
NSY-20/3.1
WSY-20/1.1
WSY-20/3.1
JSY-20/1.1
JSY-20/3.1
25-50
NSY-20/1.2
NSY-20/3.2
WSY-20/1.2
WSY-20/3.2
JSY-20/1.2
JSY-20/3.2
70-120
NSY-20/1.3
NSY-20/3.3
WSY-20/1.3
WSY-20/3.3
JSY-20/1.3
JSY-20/3.3
150-240
NSY-20/1.4
NSY-20/3.4 
WSY-20/1.4 
WSY-20/3.4 
JSY-20/1.4
JSY-20/3.4
300-400 
 
35KV heat shrinkable cable terminaltion and joint
Items
Typical data
AC withstand for 1min
105kv/min
DC negative polarity voltage withstand 
156Kv/15min
Partial discharge 
≤20Pc
Impulse voltage withstand
250kv
AC withstand for 4h
104kv


Indoor termination
Outdoor termination
Straight through joint
size of conductor
(mm2)
Single core
Three cores
Single core
Three cores
Single core
Three cores
 
NSY-35/1.2
NSY-35/3.2
WSY-35/1.2
WSY-35/3.2
JSY-35/1.2
JSY-35/3.2
50-120
NSY-35/1.3
NSY-35/3.3
WSY-35/1.3
WSY-35/3.3
JSY-35/1.3
JSY-35/3.3
150-240
NSY-35/1.4
NSY-35/3.4 
WSY-35/1.4 
WSY-35/3.4 
JSY-35/1.4
JSY-35/3.4
300-500