10KV-35kv heat shrinkable cable terminaltion and joint
For PVC.XLPE Rubber-plastic insulated 1-core 2-cores 3-cores 4-cores 5cores power cable heat shrinkable termination .
Feature
1. Preferable electrical appliance function
2. Reliable insulation
3. Superior hermetic sealing
4. Excellent heat /cold proof ,waterproof ,Anti-aging ,
5. widely used at the field of electric power, electronic, petroleum,
chemical engineering, construction and communication
35kV cable heat shrinkable termination and Sraight through joint
10kv-35kV High-voltage products of cable termination are mainly and universally applied to dealing with disconnection place of Cable below 10kv-35kV. In cable cores, products are classified single core, three cores.etc.
10KV heat shrinkable cable terminaltion and joint
Items
|
Typical data
|
AC withstand for 1min
|
45kv/min
|
DC negative polarity voltage withstand
|
52Kv
|
Partial discharge
|
≤20Pc
|
Impulse voltage withstand
|
105kv
|
AC withstand for 4h
|
35kv
|
Indoor termination
|
Outdoor termination
|
Straight through joint
|
size of conductor
(mm2)
|
|||
Single core
|
Three cores
|
Single core
|
Three cores
|
Single core
|
Three cores
|
|
NSY-10/1.1
|
NSY-10/3.1
|
WSY-10/1.1
|
WSY-10/3.1
|
JSY-10/1.1
|
JSY-10/3.1
|
25-50
|
NSY-10/1.2
|
NSY-10/3.2
|
WSY-10/1.2
|
WSY-10/3.2
|
JSY-10/1.2
|
JSY-10/3.2
|
70-120
|
NSY-10/1.3
|
NSY-10/3.3
|
WSY-10/1.3
|
WSY-10/3.3
|
JSY-10/1.3
|
JSY-10/3.3
|
150-240
|
NSY-10/1.4
|
NSY-10/3.4
|
WSY-10/1.4
|
WSY-10/3.4
|
JSY-10/1.4
|
JSY-10/3.4
|
300-400
|
20KV heat shrinkable cable terminaltion and joint
Items
|
Typical data
|
|||||
AC withstand for 1min
|
56kv/min
|
|||||
DC negative polarity voltage withstand
|
96Kv
|
|||||
Partial discharge
|
≤20Pc
|
|||||
Impulse voltage withstand
|
125kv
|
|||||
AC withstand for 4h
|
48kv
|
|||||
Indoor termination
|
Outdoor termination
|
Straight through joint
|
size of conductor
(mm2)
|
|||
Single core
|
Three cores
|
Single core
|
Three cores
|
Single core
|
Three cores
|
|
SY-20/1.1
|
NSY-20/3.1
|
WSY-20/1.1
|
WSY-20/3.1
|
JSY-20/1.1
|
JSY-20/3.1
|
25-50
|
NSY-20/1.2
|
NSY-20/3.2
|
WSY-20/1.2
|
WSY-20/3.2
|
JSY-20/1.2
|
JSY-20/3.2
|
70-120
|
NSY-20/1.3
|
NSY-20/3.3
|
WSY-20/1.3
|
WSY-20/3.3
|
JSY-20/1.3
|
JSY-20/3.3
|
150-240
|
NSY-20/1.4
|
NSY-20/3.4
|
WSY-20/1.4
|
WSY-20/3.4
|
JSY-20/1.4
|
JSY-20/3.4
|
300-400
|
35KV heat shrinkable cable terminaltion and joint
Items
|
Typical data
|
AC withstand for 1min
|
105kv/min
|
DC negative polarity voltage withstand
|
156Kv/15min
|
Partial discharge
|
≤20Pc
|
Impulse voltage withstand
|
250kv
|
AC withstand for 4h
|
104kv
|
Indoor termination
|
Outdoor termination
|
Straight through joint
|
size of conductor
(mm2)
|
|||
Single core
|
Three cores
|
Single core
|
Three cores
|
Single core
|
Three cores
|
|
NSY-35/1.2
|
NSY-35/3.2
|
WSY-35/1.2
|
WSY-35/3.2
|
JSY-35/1.2
|
JSY-35/3.2
|
50-120
|
NSY-35/1.3
|
NSY-35/3.3
|
WSY-35/1.3
|
WSY-35/3.3
|
JSY-35/1.3
|
JSY-35/3.3
|
150-240
|
NSY-35/1.4
|
NSY-35/3.4
|
WSY-35/1.4
|
WSY-35/3.4
|
JSY-35/1.4
|
JSY-35/3.4
|
300-500
|