Product Main

Specifications

OPT6300 is an optical protection equipment which is able to provide fiber path redundancy on a channel by channel basis.
OPT6300 is special for  the protection for fiber data transmission which has monitoring capacities for both working and protection paths.  
OPT6300 is a desktop equipment which is convenient for the local accessing optical networks.  

Features
■ 1+1 full protection, 1:1 redundancy protection and by-pass protection are available.
■ It can restore the traffic in a < 50ms short time  automatically to minimize interruption of fiber data.
■ It provides the transparent transmission over fiber with the high-reliability, flexibility and robustness
■  Besides the optical line protection switching function, it also provides real-time monitoring capacities.
■  It provides latching feature, if the power is lost the switch will remain in its current status.
■  It provides AC and DC power supply as options  for 1+1 power redundancy protection
■  With the built-in watchdog, it can make sure the equipment never shutdown.
■ Support TFTP updating and on-line diagnostics from the remote side
■  It provides EMS system using GUI interface for the remote management.    

 
Parameters
Unit
Values
Working Wavelength Range(1)
nm
1310± 50, 1550± 50
Optical Input Power
mW
< 300
Insertion Loss @1550nm
1+1 Protection(2)
dB
Tx Side: ≤ 4.0 ;   Rx Side: ≤ 1.5
1:1 Protection
dB
  ≤ 1.5
Return Loss
dB
≥ 45
Cross-talk
dB
≥ 55
Power Monitoring Range(3)
Tx Side
dBm
-35~+25
Rx Side
dBm
-50~+10
Power Measuring Resolution
dB
≤ 0.1
Power Measuring Accuracy
dB
≤ 1.0 
Wavelength Dependent Loss
dB
≤ 0.25
Polarization Dependent Loss
dB
≤ 0.1
Switching time
1+1 Protection
ms
Normal: 5  ;   Max: 10
1:1 Protection
ms
Normal: 10 ;     Max: 15
 
Notes
(1)      The working wavelength covers these band:  
Conventional Band 1530~1565nm;
Long Band 1565~1625nm;
Original Band 1260~1360nm.
(2)      The insertion loss in 1+1 protection Tx side majorly comes from 50:50 optical splitter system.
(3)      As for the power monitoring range, Tx refers to the path from OLP to the trunk fiber; Rx refers to the path from trunk fiber to OLP including working fiber and protected fiber).


   
Parameters
Values
Management Port
Console, Telnet,
Interfaces
FE Ethernet Port
RS232 Console
Model Switch
6× SC/6× FC Optical
Display
LCD 32× 160 pixels
Physical Dimensions
440(W)× 220(D)× 44.5(H)
Power Supply:
AC  220V (100~276V)
DC  48V    (-70 ~ -35V)
Power Consumption
< 5W
Temperature:
Operating 0~ 60 deg
Storage  -40~ 85 deg
Humidity
5% ~ 95% Non. Den
Gross Weight
< 4kg
Reliability
MTBF< 105 Hours