OPT6300 is an optical protection equipment which is able to provide fiber path redundancy on a channel by channel basis.
OPT6300 is special for the protection for fiber data transmission which has monitoring capacities for both working and protection paths.
OPT6300 is a desktop equipment which is convenient for the local accessing optical networks.
|
Features
|
|
■ 1+1 full protection, 1:1 redundancy protection and by-pass protection are available.
|
|
■ It can restore the traffic in a < 50ms short time automatically to minimize interruption of fiber data.
|
|
■ It provides the transparent transmission over fiber with the high-reliability, flexibility and robustness
|
|
■ Besides the optical line protection switching function, it also provides real-time monitoring capacities.
|
|
■ It provides latching feature, if the power is lost the switch will remain in its current status.
|
|
■ It provides AC and DC power supply as options for 1+1 power redundancy protection
|
|
■ With the built-in watchdog, it can make sure the equipment never shutdown.
|
|
■ Support TFTP updating and on-line diagnostics from the remote side
|
|
■ It provides EMS system using GUI interface for the remote management.
|
|
Parameters
|
Unit
|
Values
|
|
|
Working Wavelength Range(1)
|
nm
|
1310± 50, 1550± 50
|
|
|
Optical Input Power
|
mW
|
< 300
|
|
|
Insertion Loss @1550nm
|
1+1 Protection(2)
|
dB
|
Tx Side: ≤ 4.0 ; Rx Side: ≤ 1.5
|
|
1:1 Protection
|
dB
|
≤ 1.5
|
|
|
Return Loss
|
dB
|
≥ 45
|
|
|
Cross-talk
|
dB
|
≥ 55
|
|
|
Power Monitoring Range(3)
|
Tx Side
|
dBm
|
-35~+25
|
|
Rx Side
|
dBm
|
-50~+10
|
|
|
Power Measuring Resolution
|
dB
|
≤ 0.1
|
|
|
Power Measuring Accuracy
|
dB
|
≤ 1.0
|
|
|
Wavelength Dependent Loss
|
dB
|
≤ 0.25
|
|
|
Polarization Dependent Loss
|
dB
|
≤ 0.1
|
|
|
Switching time
|
1+1 Protection
|
ms
|
Normal: 5 ; Max: 10
|
|
1:1 Protection
|
ms
|
Normal: 10 ; Max: 15
|
|
|
Notes
(1) The working wavelength covers these band:
Conventional Band 1530~1565nm;
Long Band 1565~1625nm;
Original Band 1260~1360nm.
(2) The insertion loss in 1+1 protection Tx side majorly comes from 50:50 optical splitter system.
(3) As for the power monitoring range, Tx refers to the path from OLP to the trunk fiber; Rx refers to the path from trunk fiber to OLP including working fiber and protected fiber).
|
|||
|
Parameters
|
Values
|
|
Management Port
|
Console, Telnet,
|
|
Interfaces
|
FE Ethernet Port
RS232 Console
Model Switch
6× SC/6× FC Optical
|
|
Display
|
LCD 32× 160 pixels
|
|
Physical Dimensions
|
440(W)× 220(D)× 44.5(H)
|
|
Power Supply:
|
AC 220V (100~276V)
DC 48V (-70 ~ -35V)
|
|
Power Consumption
|
< 5W
|
|
Temperature:
|
Operating 0~ 60 deg
Storage -40~ 85 deg
|
|
Humidity
|
5% ~ 95% Non. Den
|
|
Gross Weight
|
< 4kg
|
|
Reliability
|
MTBF< 105 Hours
|