Product Main

Specifications

Racotech manufactures advanced precision seismic geophones for high definition land, transitional zone and marsh zone applications, with the frequency covering from 4.5Hz, 8Hz, 10Hz, 14Hz, 28Hz, 40Hz, 60Hz to 100Hz.
 
RGI-HP103 (SM24) Geophone Element
SPECIFICATION| Specified at 20?C 
Frequency 
Natural Frequency 10 Hz±2.5%
Max. tilt angle for specified fn 10?
Typical spurious frequency >240 Hz
Distortion 
Distortion coil to case velocity with 0.7 in/s p.p. coil <0.10%
Distortion measurement frequency 12 Hz
Max. tilt angle for distortion specification 10?
Damping 
Typical open-circuit damping 0.25
Damping calibration shunt 1339Ω  0.60
Damping calibration shunt 1000Ω  0.69
Tolerance with calibration-shunt 0 to 5%
Coil Resistance 
Standard 375Ω±2.5%
Sensitivity 
Sensitivity 28.8 V/m/s±2%
Sensitivity with 1339Ω shunt resistor 22.5 V/m/s±2.5%
Sensitivity with 1000Ω shunt resistor 20.95 V/m/s±2.5%
Physical Characteristics 
Moving mass 11g
Maximum coil excursion p.p. 2mm
Diameter 25.4mm
Height 32.0mm
Weight 85g
Operating temperature range -40?C to +100?C
 
RGI-HP102 (32CT) Geophone Element
SPECIFICATION| Specified at 25?C 
Frequency 
Natural Frequency 10 Hz±2.5%
Max. tilt angle for specified fn 20?
Typical spurious frequency ≥250 Hz
Distortion 
Distortion coil to case velocity with 0.7 in/s p.p. coil <0.10%
Distortion measurement frequency 12 Hz
Tilt angle for distortion specification 10?
Damping 
Typical open circuit damping 0.316±2.5%
Damping calibration shunt resistance 1000Ω
Damping with calibration shunt 0.70±2.5%
Coil Resistance 
Standard 395Ω±2.5%
Sensitivity 
Sensitivity 27.5 V/m/s±2.5%
Sensitivity with 1000Ω shunt resistor 19.7 V/m/s±2.5%
Physical Characteristics 
Moving mass 11.2g
Maximum coil excursion p.p. 1.52mm
Diameter 25.4mm
Height 33.0mm
Weight 89g
Operating temperature range -40?C to +100?C