Product Main

Specifications

We are a supplier and exporter of  Ultrasonic Thickness Gauge,sound level meters,anemometers,lux meters,dew point meters,humidity/temperature meters,thickness meters,vibration meters,hardness testers,leeb hardness tester,brinell hardness tester,rockwell hardness tester,vickers hardness tester, force&tension gauges,test stands,shore durometers,ultrasonic flaw detectors,multimeters, clamp meters,IR thermometers,range finders,gas detectors,diamond testers,etc...

Ultrasonic Thickness Gauge UM-5
Single-crystal delayed probe is employed by UM-5 precise ultrasonic thickness gauge. The multi-echo is used to enhance the accuracy with the resolution of 0.0001 and the low limit of 0.012. There are two operating modes of M-3 ultrasonic thickness gauge: I-E (interface-echo) mode and E-E mode. The measuring range of I-E mode is 0.059-0.709, while the measuring range of E-E mode is 0.012-0.394.
Standard package:
UM-5 thickness gauge Standard probe (single-crystal delayed probe) Carrying case Two 1.5V AA alkaline batteries Couplant Operating manual Certification of quality Packaging list
Operating principle:
 I-E (interface-echo) mode with single-crystal delayed probe E-E (echo-echo) mode with single-crystal delayed probe
Measuring range:
1.5mm to 18mm; 0.059in-0.709in in I-E mode 0.25mm to 10mm; 0.012in-0.394in in E-E mode Depending on probe, material and surface condition
Digital resolution:
 H less than 0.4in : 0.0001in/ 0.001in/ 0.01in or 0.001mm/0.01mm/0.1mm H more than or equal to 0.4in : 0.001in/ 0.01in or 0.01mm/0.1mm
Units:
 Selectable: inch or mm
Display:
128?4 dot-matrix LCD screen (1.65in?.24in; 42mm?7mm) EL backlight and switchable contract ratio Digit height: 0.54in or 13.75mm
Measurement update rate:
 4 Hz in standard measurement mode 25 Hz in MIN capture mode
Material velocity range:
 1000 to 9999 m/s; 0.039 to 0.394 inch/µs
Power:
Two 1.5V AA alkaline batteries Warning with low battery voltage
Operating time:
Up to 200 hours (without backlight) with alkaline batteries, depending on operating mode
Auto shut-off:
After 5 minutes of non-use
Operating temperature:
 -10C to +50C; +14F to +122F Specification to -20C/-4F on request
Size
 5.86in?.87in?.25in; 149mm?3mm?2mm
Weight:
200g / 0.44lb (including batteries)
Data logger capacity:
Up to 500 readings can be divided into a maximum of 5 files (user-selectable)
Optional accessories:
 Attachable rubber case Numerous special probes on request Couplants and high-temperature couplant 4-step/6-step block for calibration Data transmission cable Application software
Operating language:
English and Chinese
Interfaces:
Serial RS 232C port in combination with a communicative cable; Data transfer parameters: 8 bits, 1 stop bit 9600 baud, no parity.