Product Main

Specifications

Variable Speed Drives transformers
 
Our combination transformer, (also called American box transformer) combines the body of transformer, switch, and fuse, and other accessories.
There are two high voltage load switches; terminal and ring which could apply for different distribution network systems. It is compact, small and quick to install.
It could go into the charge center, improve the power supply. It could also satisfy the requirement as the calculation of consummation, reimbursement, low voltage division. It is easy to operate.
 
Application of Variable Speed Drives transformers
 
It could be used outdoors as well as indoors, for example; In residential area, airport, apartment, commercial center, mines, hospital and school etc.
Main Characters of Combination Transformer:
Main Characters of Application of American Box Transformer:
1• All insulated structure and interlocking devices to ensure safety.
2• All sealed structure, free from oil quality degeneration, prolong the life of transformer.
3• Charging switches are interacted in three phased which reduces the resonance of iron and magnet;
4• Double fuse protection, to assure the system simple, convenient, economical and reliable;
5• Silicon steel core, amorphous alloy core, coiled core etc; low loss, low noise, and no temperature raising on box surface;
6• High voltage line plug cable is elbow style and can operation 200A charging current.
In emergency, it could operate the charging switch. It could be insulated from switch.
7• Small size, only 1/3 of European style box.
 
 
Variable Speed Drives transformers
technical parameter
 
Ratedpower
(KVA)
Voltage
Connection
9 loss(KW)
11 loss(KW)
No-load Current (%)
Impedance Voltage (%)
Noise(db)
Exotherm
(k)
H.V(KV)
L.V(KV)
No-Load Loss
Load Loss
No-Load Loss
Load Loss
30
6
6.3
10
10.5
11
±5%
or
±2×
2.5%
0.4
Yyn0
or
Dyn11
130
600
100
600
2.1
4
55
Top level 55

Winding 65
50
170
870
130
870
2
63
200
1040
150
1040
1.9
80
250
1250
180
1250
1.9
100
290
1500
200
1500
1.8
125
340
1800
240
1800
1.7
160
400
2200
280
2200
1.6
200
480
2600
340
2600
1.5
250
560
3050
400
3050
1.4
315
670
3650
480
3650
1.4
400
800
4300
570
4300
1.3
500
960
5100
680
5100
1.2
630
1200
6200
810
6200
1.1
800
1400
7500
980
7500
1.0
4.5
1000
1700
10300
1150
10300
1.0
1250
1950
12000
1360
12000
0.9
1600
2400
14500
1640
14500
0.9
Variable Speed Drives transformers
dielectric level
 
Rated voltage (root mean)
Highest voltage (root mean)
Rated lightning impulse withstand voltage     (peak value)
Rated short-term frequency voltage tolerance (Imin) (root mean)
double wave
carrier wave
6
7.2
60
65
25
10
12
75
85
35
 
High-voltage electrical apparatus element dielectric level
 
Rated voltage
(root mean)
Highest voltage
(root mean)
Rated lightning impulse withstand voltage       (peak value)
Rated short-term frequency voltage tolerance  (Imin)     (root mean)
to ground and interlinked tension
Isolation clearance
to ground and interlinked tension
Isolation clearance
6
7.2
60
70
32
35
10
12
75
85
42
48
 
 Low-voltage electrical apparatus element dielectric level
 
Rated voltage
60<Ui≤300
300<Ui≤600
660<Ui≤800
800<Ui≤1000
Rated short-term frequency voltage tolerance (Imin)  (root mean)
2000
2500
3000
3500
 
Furnace Transformer
Combined type transformer dielectric level
Model
Rated power KVA
Number of Phases
Voltage
loss(KW)
No-load Loss (%)
No-load Loss (%)
H.V(KV)
L.V(KV)
No-Load Loss
Load Loss
HSK-100
100
3
0.38
95
105
115
0.36
4
3.3
5
HSK-150
150
3
0.38
95
110
165
0.44
4.32
3.2
5
HSK-180
180
3
0.38
80
85
90
0.6
4.8
2.8
5
HSK-200
200
0.65
5.6
2.6
5
HSK-220
220
0.8
6
2.5
5
HSK-260
260
0.96
7.6
2.3
5
HSK-300
300
3
0.38
90
95
100
1
8
2.1
5
HSK-350
350
3
6.3(10)
95
110
165
190
1.45
8.6
1.8
5
HSK-400
400
3
6.3(10)
2
10
1.8
5
HSK-500
500
3
6.3(10)
100
115
175
200
2.3
14
1.5
6
HSK-630
630
3
6.3(10)
98
116
170
200
2.45
15
1.3
8
HSK-800
800
3
6.3(10)
3
17
1.1
9
HSK-1000
1000
3
6.3(10)
3.6
20
1.1
9
HSK-1250
1250
3
6.3(10)
104
121
180
210
3.8
23
0.85
10
HSK-1600
1600
3
6.3(10)
5
28
0.85
10
HSK-2000
2000
3
6.3(10)
6.5
36
0.6
10
HSK-2500
2500
3
6.3(10)
110
127
190
220
8.3
52
0.6