50KW High Frequency X-ray unit YSX0607
1)Microcomputer control x-ray radiography assembles: optional 600mA or 50KW.
2)Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.
3)X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
4)Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.
5)Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest.
1)Microcomputer control x-ray radiography assembles: optional 600mA or 50KW.
2)Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.
3)X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
4)Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.
5)Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest.
Department
|
Technology parameters
|
||||||
High voltage generator control table and high voltage transform assemble
|
Fluoroscopy
|
Tube currency
|
0.2-12.5mA continuous currency
|
||||
Tube voltage
|
40-150KV continuous voltage
|
||||||
Radiography
|
Tube currency
|
10-630mA shift
|
|||||
Tube voltage
|
40-150KV continuous voltage
|
||||||
Exposure time
|
0.01-10s 23 shift
|
||||||
Power
|
Voltage
|
380V±10%
|
|||||
Frequency
|
50Hz±1Hz
|
||||||
Capacity
|
≥50KVA
|
||||||
Inner resistance
|
≤0.15Ω
|
||||||
X-ray assembly
|
Power
|
50KW
|
|||||
Thermal Capacity
|
230kHU
|
||||||
Double focal
|
0.6/1.2mm
|
||||||
Changed beam limited device
|
Diagnosis table YS09D
|
Automatic, adjusted field of view
|
|||||
CDG
Multi function radiography table
|
Moving table
|
Lengthways
|
±600mm
|
Electromagnetism locking
|
|||
Across
|
±120mm
|
|
|||||
Mobile beam filtration grid
|
Grid density
|
28L/cm
|
|||||
Grid ratio
|
8:1
|
||||||
Focusing distance
|
100cm
|
||||||
Scope of moving
|
≥600mm
|
||||||
Radiography item
|
5”×7”,8”×10”,10”×12”,11”×14”,
12”×15”,14”×14”,14”×17”
|
||||||
Distance from surface to film
|
75mm
|
||||||
Height of bed
|
700mm
|
||||||
Moving pillar
|
±180°,per 90°orientation, moving lengthways ≥1500mm
|
||||||
Bulb tube
|
Rotate the cross arm±180,ascend $ descend 1100mm
|
||||||
CS15
Electro-motion diagnostic table
|
The table body rotation
|
-15°~0°~+90°
|
|||||
Focus to film distance
|
1100~1500mm,adjustable manual
|
||||||
360°foot board
|
|||||||
The table to height
|
870mm
|
||||||
Stationary grid
|
Grid density
|
40L/cm
|
|||||
Grid ration
|
10:1
|
||||||
Focusing distance
|
120cm
|
||||||
Spot film device
|
Scope of moving
|
Longitudinal moving:900mm;
Transverse moving:±120mm
|
|||||
Specification of scope film
|
Full :8”×10”,10”×12”,11”×14”,14”×14”
Two: 8”×10”,10”×12”
Three:11”×14”,14”×14”
Four: 11”×14”,14”×14”
|
||||||
Medical television system
|
configuration
|
9”x-ray image intensifier made by Toshiba, CCD camera,14” high resolution monitor
|
|||||
14”monitor
|
resolution
|
Horizontal center≥1000 TV line
|
|||||
Gray scale
|
≥10 grades
|
||||||
Video width
|
>12MHZ
|
||||||
Mode of scan
|
625 lines,5 field,Interlaced scanning
|
||||||
Geometry distortion
|
<2%
|
||||||
SNR
|
≥40db
|
||||||
Power supply
|
220V 50Hz AC
|
||||||
9”x-ray image intensifier made by Toshiba
|
resolution
|
≥46LP/mm
|
|||||
Conversion modulus
|
34cd/m2/μGY/s
|
||||||
Contrast
|
10% area:30:1,Φ10mm area:18:1
|
||||||
CCD
Japan Camera
|
Specification
|
1/2”,anti-halation,CCIR752×586
|
|||||
Option
|
|
||||||
LSJ pillar radiography frame
|
The scope of ascend and descend
|
1450mm
|
|||||
The minimum distance from focal spot
|
380mm
|
||||||
Radiography item
|
8”×10” 10”×12” 11”×14”12”×15”
14”×14” 14”×17”
|
||||||
Fixed beam filtration role
|
Grid density
|
40L/cm
|
|||||
Grid radio
|
10:1
|
||||||
Focal distance
|
180cm
|