Product Main

Specifications

50kW Digital X-ray System YSX0611
1. The digital medical diagnostic X-ray machine, not only retains conventional X-ray machine functions, but also has a modern digital medical diagnostic X-ray machine's various functions.
2. Digital X-ray machines for medical diagnostic physics imaging replace the traditional chemical methods (X-ray) imaging methods. It is fast imaging, convenient and easy-to-use. Its dose-ray imaging is about 1/3 of the traditional dose. It also has a digital angiography (DSA ) Subtraction, and other features.
3.The digital medical diagnostic X-ray machine features a wide range and can be used for a variety of fluoroscopy, radiograph, digital point-chip, digital gastrointestinal diagnosis and interventional radiology treatment.
3. The digital medical diagnostic X-ray machines use the 1024 × 1024 × 12bit high-resolution digital imaging systems and digital pulse with a point-chip features to make clearer images and more conducive to clinical diagnosis.
4. Digital images can be used for local area and wide area networks, remote consultation.
CD is used to store images so as to save the hospital film storage. Film printers is used to print directly film and improve efficiency, cut costs and reduce pollution, waste film.

Configuration table
No
Parts
Specification
Qty
1
High Frequency High Voltage Generator (Imported)
Power
50kW
1set
Frequency
240kHZ
Fluoroscopy
Continue Fluoroscopy
Voltage:125KVp,
Currency: 0.5-5.0 mA
Pulse Fluoroscopy
Currency
25-630mA,Pulse
Width
0.5-630mAs
Pulse rate
0.25-30p/s
Radiography
Exposure time
25-630ms
Exposure Capacity
0.5-630mAs
Tube Currency
630mA
Tube Voltage:
150kV
2
Remove Control Diagnostic table (Including the Control table)
The table body rotation
-40°~0°~+90°
1set
Transverse moving of the table
±100mm
Vertical moving of the table
±350mm
Slide moving lengthways
800mm
Distance between Focus and the film
1100mm~1500 mm
Specification of the Spot film:
Full
8”×10”,10”×12”,11”×14”,14”×14”,14”×17”
Two
8”×10”,10”×12”
Three
11”×14”,14”×14”
Four
11”×14”,14”×14”
Filtration Grid
Focusing distance 120cm,
Grid ratio:10:1,
Density: 40L/cm
3
X-ray tube assembly
(Imported)
Double focus
0.6/1.2mm
1set
Thermal Capacity
300kHU
Power
Small focus: 22kW,
big focus: 50kW
Anode rotating
8500rpm
4
Auto changed beam limited device
The rectangular radiation field can be adjusted automatically or manually according the size of the film. It has the radiation field and timer.
1set
5
Image intensifier (Imported)
Resolution
≥46LP/mm
1set
Contrast
10 %field: 24:1,
6
CCD Camera
(Imported)
Pixel
1024×1024×14bit
1set
The adjust scope of the auto-aperture
160 steps(Digital)
7
Monitor
17 inch Medical dedicated high definition display monitor
2set
8
High Voltage cable
12 m
2pcs