50kW Digital X-ray System YSX0611
1. The digital medical diagnostic X-ray machine, not only retains conventional X-ray machine functions, but also has a modern digital medical diagnostic X-ray machine's various functions.
2. Digital X-ray machines for medical diagnostic physics imaging replace the traditional chemical methods (X-ray) imaging methods. It is fast imaging, convenient and easy-to-use. Its dose-ray imaging is about 1/3 of the traditional dose. It also has a digital angiography (DSA ) Subtraction, and other features.
3.The digital medical diagnostic X-ray machine features a wide range and can be used for a variety of fluoroscopy, radiograph, digital point-chip, digital gastrointestinal diagnosis and interventional radiology treatment.
3. The digital medical diagnostic X-ray machines use the 1024 × 1024 × 12bit high-resolution digital imaging systems and digital pulse with a point-chip features to make clearer images and more conducive to clinical diagnosis.
4. Digital images can be used for local area and wide area networks, remote consultation.
CD is used to store images so as to save the hospital film storage. Film printers is used to print directly film and improve efficiency, cut costs and reduce pollution, waste film.
|
Configuration table
|
||||||
|
No
|
Parts
|
Specification
|
Qty
|
|||
|
1
|
High Frequency High Voltage Generator (Imported)
|
Power
|
50kW
|
1set
|
||
|
Frequency
|
240kHZ
|
|||||
|
Fluoroscopy
|
Continue Fluoroscopy
|
Voltage:125KVp,
|
||||
|
Currency: 0.5-5.0 mA
|
||||||
|
Pulse Fluoroscopy
|
Currency
|
25-630mA,Pulse
|
||||
|
Width
|
0.5-630mAs
|
|||||
|
Pulse rate
|
0.25-30p/s
|
|||||
|
Radiography
|
Exposure time
|
25-630ms
|
||||
|
Exposure Capacity
|
0.5-630mAs
|
|||||
|
Tube Currency
|
630mA
|
|||||
|
Tube Voltage:
|
150kV
|
|||||
|
2
|
Remove Control Diagnostic table (Including the Control table)
|
The table body rotation
|
-40°~0°~+90°
|
1set
|
||
|
Transverse moving of the table
|
±100mm
|
|||||
|
Vertical moving of the table
|
±350mm
|
|||||
|
Slide moving lengthways
|
800mm
|
|||||
|
Distance between Focus and the film
|
1100mm~1500 mm
|
|||||
|
Specification of the Spot film:
|
Full
|
8”×10”,10”×12”,11”×14”,14”×14”,14”×17”
|
||||
|
Two
|
8”×10”,10”×12”
|
|||||
|
Three
|
11”×14”,14”×14”
|
|||||
|
Four
|
11”×14”,14”×14”
|
|||||
|
Filtration Grid
|
Focusing distance 120cm,
|
|||||
|
Grid ratio:10:1,
|
||||||
|
Density: 40L/cm
|
||||||
|
3
|
X-ray tube assembly
(Imported)
|
Double focus
|
0.6/1.2mm
|
1set
|
||
|
Thermal Capacity
|
300kHU
|
|||||
|
Power
|
Small focus: 22kW,
|
|||||
|
big focus: 50kW
|
||||||
|
Anode rotating
|
8500rpm
|
|||||
|
4
|
Auto changed beam limited device
|
The rectangular radiation field can be adjusted automatically or manually according the size of the film. It has the radiation field and timer.
|
1set
|
|||
|
5
|
Image intensifier (Imported)
|
Resolution
|
≥46LP/mm
|
1set
|
||
|
Contrast
|
10 %field: 24:1,
|
|||||
|
6
|
CCD Camera
(Imported)
|
Pixel
|
1024×1024×14bit
|
1set
|
||
|
The adjust scope of the auto-aperture
|
160 steps(Digital)
|
|||||
|
7
|
Monitor
|
17 inch Medical dedicated high definition display monitor
|
2set
|
|||
|
8
|
High Voltage cable
|
12 m
|
2pcs
|
|||