High Frequency X-ray Unit YSX0302
Feature:
1. Power is 220V, 600W. Unnecessary connected special power and line. Particularly suitable for rural hospitals where the power supply is poor. It is a huge breakthrough for the high-power X-ray machine in the domestic first.
2. Optional charge storage device, charge once every ,radiography 100-300 films.
3. New products focused by the Ministry of Science and Technology
Main Technology parameters
1. Power voltage AC 220±10%
2. Power frequency 50HZ±1HZ
3. Power capacity ≥600W
4. Power inner resistance ≤10
5. Max tube voltage 125kv
6. High voltage putout power: 20 KHz
7. High voltage putout frequency: 30 KHz
8. Tube voltage 40~125kv
9. Currency time 0.5~125mAs 40 shift
10. Focal small focal: 1mm2, big focal: 2mm2,
11. Rated rotate speed of anode: 2800r/min
12. Radiography table (length×brand×high) 2100×790×700mm
13. Scope of the moving table: moving lengthways: 820mm moving crossive235mm
14. up and down scope of pillar: 1600mm
15. rotated pillar 0° ±90° 180° orientation
16. distance between the table and film: ≤60mm
17. x-ray assemble rotated around the arm ±900
18. Beam filtration device fixed beam filtration grid N=40line/cm
19. Limit beam filtration device lightspot orientation optional CR image system
Frame:
Single tube high frequency high voltage generator
Control table
High frequency x-ray tube assemble
High voltage cable (2)
Beam filtration device
Feature:
1. Power is 220V, 600W. Unnecessary connected special power and line. Particularly suitable for rural hospitals where the power supply is poor. It is a huge breakthrough for the high-power X-ray machine in the domestic first.
2. Optional charge storage device, charge once every ,radiography 100-300 films.
3. New products focused by the Ministry of Science and Technology
Main Technology parameters
1. Power voltage AC 220±10%
2. Power frequency 50HZ±1HZ
3. Power capacity ≥600W
4. Power inner resistance ≤10
5. Max tube voltage 125kv
6. High voltage putout power: 20 KHz
7. High voltage putout frequency: 30 KHz
8. Tube voltage 40~125kv
9. Currency time 0.5~125mAs 40 shift
10. Focal small focal: 1mm2, big focal: 2mm2,
11. Rated rotate speed of anode: 2800r/min
12. Radiography table (length×brand×high) 2100×790×700mm
13. Scope of the moving table: moving lengthways: 820mm moving crossive235mm
14. up and down scope of pillar: 1600mm
15. rotated pillar 0° ±90° 180° orientation
16. distance between the table and film: ≤60mm
17. x-ray assemble rotated around the arm ±900
18. Beam filtration device fixed beam filtration grid N=40line/cm
19. Limit beam filtration device lightspot orientation optional CR image system
Frame:
Single tube high frequency high voltage generator
Control table
High frequency x-ray tube assemble
High voltage cable (2)
Beam filtration device