Product Main

Specifications

50kw High frequency radiography x-ray unit YSX0308
Characteristic
1. It is microcomputer procedure control and high frequency single x-ray tube and diagnostic table x-ray equipment.
2. To be equipped with 150kV, 50kW X-ray tube. High-frequency technology Constant DC output, not only improve the image quality and greatly reduce the radiation hazards to patients.
3. Main circuit using intelligent modules, not only to improve the radiation output reproducibility and linearity, while ensuring long-term safety of the machine is running reliably and has fault self-diagnosis function.
4. The machine has 2000 kinds of exposure conditions, also, exposure conditions can be chooses according to user’s demand, which providing a great convenience for clinical use.
5. The vertical and horizontal movement of radiography tabletop is flexible and can bear for a variety of specifications of cassettes; it is easy to use and beautiful in design.
6. It is applicable to the hospital for general photography, photographic filter line browser, apparatus procedures radiography (APR), etc.

 

Department
Technical parameter
High frequency generator
Power
Voltage
380V±10%
frequency
50Hz±1Hz
capacity
≥50KVA
Internal resistance
≤0.15Ω
AEC control time
Min. 4ms
mAs
1~630 mAs
Radiography
current
32-630mA  adjustable dividedly
voltage
45-125KV  adjustable continuously
Time of exposure
0.01-6.3s ,23 grades
Mode of choice
Save a total of 128 kinds of exposure conditions, can also be freely chosen by the operator
X-ray assembly
Output power
≥22/54kW
Anode heat storage capacity
≥230kHU
focus
Double focus 0.6/1.2mm
Speed of anode rotating
2800r/min
Imported Collimator
radiation field
Manual adjustable field of view, adjustable continuously
Light field
luminosity≥100LX,1min limit-time device
CDG/CDGI Multi function radiography table
Moving table
Lengthways
±600mm
Electromagnetism locking
Across
±120mm
Mobile beam filtration grid
Grid density
28L/cm
Grid ratio
8:01
Focusing distance
100cm
Scope of moving
≥600mm
Radiography item
5”×7”,8”×10”,10”×12”,11”×14”,
12”×15”,14”×14”,14”×17”
Distance from surface to film
75mm
Height of bed
700mm
Moving pillar
±180°,per 90°orientation, moving lengthways ≥1500mm
Bulb tube
Rotate the cross arm±180,ascend $ descend 1100mm
             
 Option

 

LSJ pillar radiography frame
The scope of ascend and descend
1450mm
The minimum distance from focal spot
380mm
Radiography item
8”×10” 10”×12” 11”×14”12”×15”
14”×14” 14”×17”
Fixed beam filtration role
Grid density
40L/cm
Grid radio
10:01
Focal distance
180cm