20kW High Frequency X-ray Equipment YSX0309
Characteristic
1. It is microcomputer procedure control and high frequency single x-ray tube and diagnostic table x-ray equipment.
2. To be equipped with 150kV, 50kW X-ray tube. High-frequency technology Constant DC output, not only improve the image quality and greatly reduce the radiation hazards to patients.
3. Main circuit using intelligent modules, not only to improve the radiation output reproducibility and linearity, while ensuring long-term safety of the machine is running reliably and has fault self-diagnosis function.
4. The machine has 2000 kinds of exposure conditions, also, exposure conditions can be chooses according to user’s demand, which providing a great convenience for clinical use.
5. The vertical and horizontal movement of radiography tabletop is flexible and can bear for a variety of specifications of cassettes; it is easy to use and beautiful in design.
6. It is applicable to the hospital for general photography, photographic filter line browser, apparatus procedures radiography (APR), etc.
Characteristic
1. It is microcomputer procedure control and high frequency single x-ray tube and diagnostic table x-ray equipment.
2. To be equipped with 150kV, 50kW X-ray tube. High-frequency technology Constant DC output, not only improve the image quality and greatly reduce the radiation hazards to patients.
3. Main circuit using intelligent modules, not only to improve the radiation output reproducibility and linearity, while ensuring long-term safety of the machine is running reliably and has fault self-diagnosis function.
4. The machine has 2000 kinds of exposure conditions, also, exposure conditions can be chooses according to user’s demand, which providing a great convenience for clinical use.
5. The vertical and horizontal movement of radiography tabletop is flexible and can bear for a variety of specifications of cassettes; it is easy to use and beautiful in design.
6. It is applicable to the hospital for general photography, photographic filter line browser, apparatus procedures radiography (APR), etc.
Department
|
Technical parameter
|
|||
High frequency generator
|
Power
|
Voltage
|
380V±10%
|
|
frequency
|
50Hz±1Hz
|
|||
capacity
|
≥50KVA
|
|||
Internal resistance
|
≤0.15Ω
|
|||
AEC control time
|
Min. 4ms
|
|||
mAs
|
1~200 mAs
|
|||
Radiography
|
current
|
32-200mA adjustable dividedly
|
||
voltage
|
45-125KV adjustable continuously
|
|||
Time of exposure
|
0.01-6.3s ,23 grades
|
|||
Mode of choice
|
Save a total of 128 kinds of exposure conditions, can also be freely chosen by the operator
|
|||
X-ray assembly
|
Output power
|
≥22/54kW
|
||
Anode heat storage capacity
|
≥230kHU
|
|||
focus
|
Double focus 0.6/1.2mm
|
|||
Speed of anode rotating
|
2800r/min
|
|||
Imported Collimator
|
radiation field
|
Manual adjustable field of view, adjustable continuously
|
||
Light field
|
luminosity≥100LX,1min limit-time device
|
|||
CS15 Electro-motion diagnostic table
|
The table body rotation
|
-15°~0°~+90°
|
||
Focus to film distance
|
1100~1500mm,adjustable manual
|
|||
360°foot board
|
||||
The table to height
|
870mm
|
|||
Stationary grid
|
Grid density
|
40L/cm
|
||
Grid ration
|
10:01
|
|||
Focusing distance
|
120cm
|
|||
Spot film device
|
Scope of moving
|
Longitudinal moving:900mm;
|
||
Transverse moving:±120mm
|
||||
Specification of scope film
|
Full:8”*10”,10”*12”,11”*14”,14”*14”
|
|||
Two: 8”*10”,10”*12”
|
||||
Three:11”*14”,14”*14”
|
||||
Four: 11”*14”,14”*14”
|
||||
CDGI Multi function radiography table
|
Moving table
|
Lengthways
|
±600mm
|
Electromagnetism locking
|
Across
|
±120mm
|
|||
Mobile beam filtration grid
|
Grid density
|
28L/cm
|
||
Grid ratio
|
8:01
|
|||
Focusing distance
|
100cm
|
|||
Scope of moving
|
≥600mm
|
|||
Radiography item
|
5”*7”,8”*10”,10”*12”,11”*14”,
|
|||
12”*15”,14”*14”,14”*17”
|
||||
Distance from surface to film
|
75mm
|
|||
Height of bed
|
700mm
|
|||
Moving pillar
|
±180°,per 90°orientation, moving lengthways ≥1500mm
|
|||
Bulb tube
|
Rotate the cross arm±180,ascend $ descend 1100mm
|
Option
LSJ pillar radiography frame
|
The scope of ascend and descend
|
1450mm
|
|
The minimum distance from focal spot
|
380mm
|
||
Radiography item
|
8”*10” 10”*12” 11”*14”12”*15”
14”*14” 14”*17”
|
||
Fixed beam filtration role
|
Grid density
|
40L/cm
|
|
Grid radio
|
10:1
|
||
Focal distance
|
180cm
|