500mA Medical X-ray Equipment YSX0228
1)Equipped with double diagnostic table and x-ray rubes, tube voltage is 125kV, tube currency is 500 mA, single direct bridge full-wave commutation.
2)X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protecionare provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
3)Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.
4)Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.
5)Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest.
6)With the X-TV system and topography device interface, the function of compartment TV remote control can be upgraded.

Department
Technology parameters
High voltage generator control table and high voltage transform assemble
Fluoroscopy
Tube currency
0.3-5mA continuous currency
Tube voltage
50-110KV continuous voltage
Radiography
Tube currency
100-500mA shift
Tube voltage
45-125KV continuous voltage
Exposure time
0.02-5s, 23 shift
Power
Voltage
380V±10%
Frequency
50Hz±1Hz
Capacity
≥30KVA
Inner resistance
≤0.3Ω
X-ray assembly
Type of x-ray
XD52-30.50/125
Focus
1×1.2×2 double focal
Rated rotate speed of anode
2800r/min
Changed beam limited device
Diagnosis table YS09D
Automatic, adjusted field of view
Radiograph table YS11S
Manually adjusted field of view, luminosity≥100LX
C15 Diagnostic table
Rotate of table
-15°~0°~90°automatic
Moving table
Automatic 700mm distance moving lengthways
Distance of focal table
400mm
High of table
820mm
Spot film device
Scope moving
Up and down
600mm
Left and right
±100mm
Forward and backward
300mm
Way of locking
Electromagnetism locking
Radiography item
5”×7”
 
 
8”×10”
 
 
10”×12”
 
11”×14”
 
 
 
CDGI
Multi function radiography table
Moving table
Lengthways
±600mm
Electromagnetism locking
Across
±120mm
Mobile beam filtration grid
Grid density
28L/cm
Grid ratio
8:1
Focusing distance
100cm
Scope of moving
≥600mm
Radiography item
5”×7”,8”×10”,10”×12”,11”×14”,
12”×15”,14”×14”,14”×17”
Distance from surface to film
75mm
Height of bed
700mm
Moving pillar
±180°,per 90°orientation, moving lengthways ≥1500mm
Bulb tube
Rotate the cross arm±180,ascend $ descend 1100mm
Option
LSJ pillar radiography frame
The scope of ascend and descend
1450mm
The minimum distance from focal spot
380mm
Radiography item
8”×10” 10”×12” 11”×14”12”×15”
14”×14” 14”×17”
Fixed beam filtration role
Grid density
40L/cm
Grid radio
10:1
Focal distance
180cm