Product Main

Specifications

Outdoor unit:
Contains two fans (blades and  motors) and aluminum finned  copper coil  heat exchanger
Outdoor unit has not pre-filled  refrigerant

Indoor unit:
Contains :
Hitachi EVI R410A compressor
High  efficiency Swep plate heat exchanger
Saginomiya electronic expansion valves for throttling
Carel pressure transmitters and Saginomiya electronic expansion valve  is adopted  to control  enhanced vapor injection , optimize  performance
R410A refrigerant is pre-filled inside indoor unit.
Hot water pump Wilo RS25/8, three way valve Honeywell VC6013  and electric heater 3/6/9kw  (Optional)
Built-in differential pressure flow switch
Hiseer self-developed  controller with remote control, user-friendly interface ,easy to understand and operate.
Good look and long lasting galvanized sheet or stainless steel cabinet

Features:
AW13/F delivers higher capacity at low evaporating temperature thereby better responding to heating requirement thanks to EVI compressor
It also results in less supplementary heating to cover the full heating demand on the coldest days.
Workable ambient temperature range - 20℃ to 43℃.
Two speed energy saving fan motors. The speed of fan varies so only the required amount of air is utilized. The blades are specially designed to move as much air as possible at the lowest noise level.
Timer ON/OFF
Automatically turn on electric heater in pre-set time period  to heat water up to pre-set temperature to prevent  Legionnella
Free of freeze even at low ambient temperatures as outdoor unit just has refrigerant instead of water
Varied heat curve. Controlled water temperature varies according to ambient temperature
Most components are well sealed to retain heat and prevent dripping


AIR TO WATER HEAT PUMP AW10/F AW13/F
Heat output/Power consumption at 7/35℃ kW 11.0/2.8 14.0/3.6
Heat output/Power consumption at 7/45℃* kW 11.8/3.5 15.1/4.5
Heat output/Power consumption at 7/55℃* kW 11.4/4.5 14.8/5.8
Heat output/Power consumption at 2/35℃ kW 10.7/3.1 12.0/3.5
Heat output/Power consumption at 2/45℃* kW 10.4/3.5 13.5/4.6
Heat output/Power consumption at -7/35℃* kW 8.3/3.0 10.6/3.9
Heat output/Power consumption at -7/45℃* kW 8.2/3.7 10.5/4.7
Heat output/Power consumption at -10/35℃* kW 7.5/3.1 9.5/3.9
Heat output/Power consumption at -10/45℃* kW 7.4/3.8 9.4/4.8
Heat output/Power consumption at -15/35℃* kW 6.8/3.1 8.6/3.9
Heat output/Power consumption at -15/45℃* kW 6.7/3.8 8.5/4.8
Starting current  A 46 55
Power   380-415V/3PH/50Hz
Compressor   HITACHI scroll
Condenser   Brazed plate heat exchanger
Nominal flow heating medium l/s 0.52 0.67
Internal pressure drop at nominal flow kPa 24 24
Air flow m3/h 3000 5000
Nominal output fan W 220 300
Max outgoing heating medium temperature 55℃
Indoor unit dimensions(HxWxD) mm 1200x650x400 1200x650x400
outdoor unit dimensions(HxWxD) mm 855x980x350 880x1150x350
Pipe connector   DN25 DN25
Indoor unit Weight kg 150 150
outdoor unit Weight kg 50 70
The above data is tested by EN14511      
* : EVI is operating.