HC12-10(D)-TF series provide automatic lighting control function and and its 100% water-proof to ensure longer lifetime. applied in pathway, bus station, boat, parking area, home garden, school, public area, ect.
FEACTURE:
Water proof: IP 67
Micro-controller digital accuracy
PWM charge mode
State of charge (SOC)
High anti-jamming capacity
Temperature compensation
Automatic detection of voltage
External temperature sensor
Single digital LED display, number equal to time setting
Big terminals and big distance between terminals
Model No. | HC12-10(F)-10A | HC12-10(F)-15A | HC12-10(F)-20A |
Rated charge and dischrege current | 10A | 15A | 20A |
System voltage | 12V; 24V/12V AUTO; | ||
Overload and short circuit protection |
1.25 rated current 60sec or 1.5 rated loads ccurrent 5 sec,
overload protection.
3 rated load current, short circuit protection.
|
||
No-load loss | <=6mA | ||
As charge,loop voltage drop | no more than 0.26V | ||
As discharge,loop voltage drop | no more than 0.15V | ||
Over-voltage protection | 17V,*2/24V | ||
Work temperature | industrial grade:-35°C to +55°C (suffix 1) | ||
Boost charge voltage | 14.6V,*2/24V(duration:10min)(available for overdischarge) | ||
Straight charge voltage | 14.4V,*2/24V(duration:10min) | ||
Floating voltage | 13.6,2*24V(duration: down to charge returns voltage) | ||
Charge returns voltage | 13.2,2*24V | ||
Temperature compensation | -4.5mV/°C/2V(boost,straight, floating, charge returns voltage compensation) | ||
Undervoltage voltage | 12.0V;*2/24V | ||
Over-discharge voltage | 11.1V to no-load voltage;*2/24V | ||
Over-discharge returns voltage | 12.6V;*2/24V | ||
Control mode |
PWM charge mode,modified discharge voltage
by the discharge rate
|
ELECTRONIC PROTECTION
Over charge or over discharge protection
Over load protection
Short circuit protection
Reverse polarity protection
Reverse current protection at night
LIGHTING CONTROL OPTION
• Press the power switch for 5 seconds, and select the desired LIGHTING CONTROL option. The LED is on, which confirmed you have selected the right one.
• The controller requires 10 minutes of continuous transition values before it starts to work. These constraints avoid false transitions due to lightning or dark storm clouds.
• 10 minutes off before the controller start to work.
A brief description follows below:
0,1,2,3,4,5,6,7
|
Hours light is turned on after sundown
|
0.
|
12 hours light is turned on after sundown
|
1.
|
Dusk-to-Dawn, light is on all light
|
2.
|
Lights remain turned off, ON/OFF mode
|
3.
|
Test mode, lights on after it detects no light, lights off after it detects light.
|
4. or 5. or 6. or 7.
|
Light is turned on for 2 hours(or 3 hrs, or 4 hrs, or 5 hrs)after sundown, turned off then, and turned on for 2 hours(or 3hrs, or 4hrs,or 5 hrs) before sunrise.
|