Product Main

Specifications

 
 
HC12-10(D)-TF series provide automatic lighting control function and and its 100% water-proof to ensure longer lifetime. applied in pathway, bus station, boat, parking area, home garden, school, public area, ect. 

FEACTURE:
 
Water proof: IP 67            
Micro-controller digital accuracy   
PWM charge mode
State of charge (SOC)         
High anti-jamming capacity       
Temperature compensation
Automatic detection of voltage  
External temperature sensor         
Single digital LED display, number equal to time setting        
Big terminals and big distance between terminals 

 
Model No. HC12-10(F)-10A HC12-10(F)-15A HC12-10(F)-20A
 Rated charge and dischrege current 10A 15A 20A
System voltage 12V; 24V/12V AUTO;
Overload and short circuit protection
1.25 rated current 60sec or 1.5 rated loads ccurrent 5 sec,
overload protection. 
3 rated load current, short circuit  protection. 
No-load loss <=6mA
As charge,loop voltage drop no more than 0.26V
As discharge,loop voltage drop no more than 0.15V
Over-voltage protection 17V,*2/24V
Work temperature industrial grade:-35°C to +55°C (suffix 1)
Boost charge voltage 14.6V,*2/24V(duration:10min)(available for overdischarge)
Straight charge voltage 14.4V,*2/24V(duration:10min)
Floating voltage 13.6,2*24V(duration: down to charge returns voltage)
Charge returns voltage 13.2,2*24V
Temperature compensation -4.5mV/°C/2V(boost,straight, floating, charge returns voltage compensation)
Undervoltage voltage 12.0V;*2/24V
Over-discharge voltage 11.1V to no-load voltage;*2/24V
Over-discharge returns voltage 12.6V;*2/24V
Control mode
PWM charge mode,modified discharge voltage 
by the discharge rate 


ELECTRONIC PROTECTION
Over charge or over discharge protection      
Over load protection
Short circuit protection                    
Reverse polarity protection
Reverse current protection at night 

LIGHTING CONTROL OPTION
 
   •  Press the power switch for 5 seconds, and select the desired LIGHTING CONTROL option. The LED is on, which confirmed you have selected the right one.
   •  The controller requires 10 minutes of continuous transition values before it starts to work. These constraints avoid false transitions due to lightning or dark storm clouds.
   •  10 minutes off before the controller start to work.
      A brief description follows below:
0,1,2,3,4,5,6,7
Hours light is turned on after sundown
 0.
12 hours light is turned on after sundown
 1.
Dusk-to-Dawn, light is on all light
2.
Lights remain turned off, ON/OFF mode
3.
Test mode, lights on after it detects no light, lights off after it detects light.
4. or 5. or 6. or 7.
Light is turned on for 2 hours(or 3 hrs, or 4 hrs, or 5 hrs)after sundown, turned off then, and turned on for 2 hours(or 3hrs, or 4hrs,or 5 hrs) before sunrise.