BITUMEN MC 30
|
Properties
|
Min
|
Max
|
Test Method
|
|
Kinemalic 1 viscosity at 60°C, eSt
|
30
|
60
|
ASTM D2170
|
|
Flash Point (Tag Open-Cup),°C
|
38
|
-
|
ASTM D1310
|
|
Distillate test 2 :
|
|
|
|
|
Distillate, percent by Volume of total 360°C
|
|||
|
To 190°C
|
-
|
15
|
ASTM D402
|
|
To 225°C
|
20
|
60
|
ASTM D402
|
|
To 260°C
|
50
|
90
|
ASTM D402
|
|
To 316°C
|
80
|
90
|
ASTM D402
|
|
Residue from distillation to 360°C, percent volume by different
|
|||
|
Test on residue from distillation Penetration at
25°C,100g, 5 sec. |
50
|
-
|
|
|
Ductility 3 at 25°C, cm
|
120
|
250
|
ASTM D402 / ASTM D113
|
|
Solubility in trichloroethylene, percent mass
|
100
|
-
|
ASTM D402 / ASTM D2024
|
|
Water, percent volume
|
-
|
0.2
|
ASTM D95
|
USES
Priming of all non-bituminous road buses, provision of temporary surfaces (deviations).
Priming of all non-bituminous road buses, provision of temporary surfaces (deviations).
APPLICATION RATE
From 0.6 litre per m² to 1.2 litre per m²
From 0.6 litre per m² to 1.2 litre per m²
SPRAYING/ALICATION TEMPERATURE
60-80? C
We also have other specification of bitumen, if you are interested in, pls contact us.
60-80? C