Features:
-Rugged construction providing shock, dust and moisture resistance
-Dual monitor position with automatic image orientation
-Automatic arc calibration and fi ber identifi cation
-User-selectable fi ber clamping method - sheath clamp or fi ber holders
-Auto-start tube heater feature
-Color LCD display with anti-refl ective coating for excellent visibility in bright sunlight
-Simultaneous battery charge and splicer operation Fonsun Technology
-Long life battery (up to 160 splice/heat cycles per charge)
-Detachable work table incorporated into the transit case
-Data and video download software included; software upgrade available via the internet
-Green friendly-RoHS & WEEE compliant
-Rugged construction providing shock, dust and moisture resistance
-Dual monitor position with automatic image orientation
-Automatic arc calibration and fi ber identifi cation
-User-selectable fi ber clamping method - sheath clamp or fi ber holders
-Auto-start tube heater feature
-Color LCD display with anti-refl ective coating for excellent visibility in bright sunlight
-Simultaneous battery charge and splicer operation Fonsun Technology
-Long life battery (up to 160 splice/heat cycles per charge)
-Detachable work table incorporated into the transit case
-Data and video download software included; software upgrade available via the internet
-Green friendly-RoHS & WEEE compliant
|
Applicable Fibers
|
SM(ITU-T G.652), MM (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655)
and other single mode fiber including ITU-T G.657 fiber |
|
Fiber count
|
Single
|
|
Applicable fiber dimensions
|
Cladding Diameter: 80μm to150μm
Coating Diameter:100μm to 1,000μm |
|
Fiber setting and cleaved length
|
Sheathe clamp A (standard) : For coating dia. up to 250um (8 to 16mm cleave),
coating dia. Of over 250um (16um cleaver) Sheathe clamp B (option) :For coating dia. up to 1000um (8 to 16mm cleave) Sheathe clamp C (option) :For 900um dia. Loose tube fiber (8 to 16mm cleave) Fiber holder (option) :FH-60-250 and FH-60-900 (10mm cleaver) |
|
Splicing Modes
|
100 preset and user programmable modes
|
|
Typical Average Splice Loss
|
0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS
(Measured by cut-back method relevant to ITU-T and IEC standards) |
|
Return loss
|
>>60dB
|
|
Splicing Time
|
Typical 9 sec. with SM FAST, 10sec. with SM AUTO and 13sec with AUTO
modes with standard SM (ITU-T G.652) |
|
Splice Loss Estimate
|
Available
|
|
Attenuation splicer function
|
Intentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an
in-line fixed attenuator |
|
Tube heater / Heating Time
|
Built-in tube heater with 30 heating modes.Typical 30 seconds with FP-03 sleeve,
|
|
Applicable Protection Sleeve
|
60mm, 40mm and Fujikura FPS01 series.
|
|
Storage of Splice Result
|
The last 2000 results to be stored in the internal memory
|
|
Tension Test
|
1.96 to 2.25N
|
|
Operating Condition
|
0 to 5,000m above sea level, 0 to 95%RH and -10 to 50 degC and up to 15m/s wind velocity, respectively
|
|
Storage Condition
|
0 to 95%RH and -40 to 80 degC respectively.
Battery:-20 to 30 degC for long term |
|
Dimensions
|
136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches)
|
|
Weight
|
2.3 kg (5.1 lbs) with AC adapter ADC-13; 2.7kg with BTR-08
|
|
Viewing Method
|
Two CMOS cameras and 4.1 inch TFT color LCD monitor
|
|
Fiber view and
Magnification |
300X for single X or Y view, or 187X for X and Y view
|
|
Power Supply
|
Applicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13, 13.2V DC with BTR-08 battery
|
|
No.of Splice Cycles with battery
|
Typical 160 cycles (splice / tube heat) with BTR-08
|
|
Electrode life
|
2500 arc-discharges
|
|
Terminals
|
USB 1.1 (Mini-B type) connector for PC communication.
6-pin Mini-DIN connector for HJS-02/03 or SH-8 power supply |
|
DESCRIPTION
|
PART #
|
|
FSM-60S Fusion Splicer (machine only)
Includes: ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), Sheath Clamp,USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual,JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap ,Fonsun Technology |
S014531
|
|
FSM-60S Fusion Splicer Kit (with cleaver)
Includes: CT30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair),Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap |
S014532
|
|
FSM-60S Fusion Splicer Kit (with cleaver, battery and cord)
Includes: BTR-08 Battery, DCC-14 Battery Charge Cord, CT-30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap |
S014562
|
|
DESCRIPTION
|
PART #
|
|
Cleavers
|
|
|
CT-30A Cleaver
|
S014080
|
|
Fiber Holders (pairs)
|
|
|
FH-60-250 Fiber Holder
|
S014548
|
|
FH-60-900 Fiber Holder
|
S014549
|
|
Batteries and Power Cords
|
|
|
ADC-13 AC Adapter
|
S014535
|
|
BTR-08 Battery
(160 splice/heat cycles) |
S014540
|
|
DCC-14 Power Cord
(connects ADC-13 to BTR-08) |
S014541
|
|
DCC-12 Power Cord
(connects ADC-13 to cigarette lighter socket) |
S013552
|
|
DCC-13 Power Cord
(connects ADC-13 to power source via alligator clips) |
S013556
|
|
Miscellaneous
|
|
|
ELCT2-20A Electrodes
|
S013532
|
|
ASW-02 Splicing Workstation
|
S010532
|
|
JP-05 Splice Sleeve Cooling Tray
|
S014537
|
|
CLAMP-S60A Sheath Clamp
(8mm min. cleave for 250um, 16mm min. cleave for 900um) |
S014550
|
|
CLAMP-S60B Sheath Clamp
(8mm min. cleave for 250um and 900um) |
S014551
|
|
CLAMP-S60 Sheath Clamp (for 900um loose tube fiber)
|
S014552
|
|
CC-24-60S Transit Case (fits only FSM-60S)
|
S014559
|
|
One Year Extended Warranty
|
S012996
|
|
Two Year Extended Warranty
|
S013000
|