1.Low temperature plasma sterilizer
2. Cassette and alarm
3. LCD operation panel
4. Low temperature and Vacuum technology
2. Cassette and alarm
3. LCD operation panel
4. Low temperature and Vacuum technology
Features:
1. Work Principle: avail the mighty penetration ability of Hydrogen Peroxide plasma when it is in vacuum state and ultraviolet ray with ultra-high intensity produced by glow discharge to kill bacterial and virus .
2. Work Temperature: ≤45°C .
3. Power Supply: 380V±10%V
4. Disinfecting Time: 45 minutes
5. Maximum disinfecting length for catheter of 1mm's internal diameter is 2000mm without any enhancer (the top for other products is 1000mm),
6. The most important standard: reach 600mm 100% sterilization for 1mm diameter stainless steel conduit(double routeway); reach 300mm 100% sterilization for 1mm diameter stainless steel conduit(single routeway).
7. Usable Volume : 50L,
8. Application scope: catheter, special multi-electrode diagnostic catheter, GL endoscope,
micro-catheters of fiber optic soft endoscope and medical or surgical instruments which are sensitive to water or heat (including operation instrument, orthopedic instrument, endoscope, laparoscope, endocrine surgical instrument etc.).
Hydrogen Peroxide Low Temperature Plasma Sterilizer is of no erosion or toxin to medical instrument. And the whole disinfecting process lasts only 45 minutes with 100% disinfecting rate.
micro-catheters of fiber optic soft endoscope and medical or surgical instruments which are sensitive to water or heat (including operation instrument, orthopedic instrument, endoscope, laparoscope, endocrine surgical instrument etc.).
Hydrogen Peroxide Low Temperature Plasma Sterilizer is of no erosion or toxin to medical instrument. And the whole disinfecting process lasts only 45 minutes with 100% disinfecting rate.
Note: Disinfection supplying room is key department to hospital and hospital infection
prevention, so the disinfection work is very important and is developing with the development of hospitals. For various catheter, precision and costly device, endoscopes which are not resist to high temperature or high pressure, Laoken brand H2O2 Low temperature plasma sterilizer is of great effect and with a complete set of sterilization quality detecting system which ensures the success of sterilization ,
prevention, so the disinfection work is very important and is developing with the development of hospitals. For various catheter, precision and costly device, endoscopes which are not resist to high temperature or high pressure, Laoken brand H2O2 Low temperature plasma sterilizer is of great effect and with a complete set of sterilization quality detecting system which ensures the success of sterilization ,