Product Main

Specifications

Product Description
This tester is a integrated tester for plug. It is used to test the breakover, insulation, high-volt, leakage current of power plug. It meets the requirements of many national and international standards such as BIS, UL, CSA, VDE, BSI, DIN, CCC, IEC, etc. It is a totally automatic testing machine make your operation more convenient and simple.

Features:
* All of the test subjects will done automatically.
* The inner/outer high-volt value and persistence time can be adjusted separately.
* Test speed is quickly, all test subjects will be achieved only in less than 2 seconds.
* The PLC control system is come from Mitsubishi, Made In Japan.
* The relay is come from Schneider, Made In French.
* If the sample is incompetent, there is a alarm by noise and alarm light.
* If the sample is incompetent, this machine will stop at once and show you which subject is incompetent.

After you push the emergency button it will restart to a new test. And a switch with key can be made to order to replace the high-volt starting button, it is very useful, because when a alarm happen, the operaters can not restart this machine, only when the managers have checked over and restart it by key the machine will be working again.
* When test over, the sample will be pushed out automatically, and a "T" or other characters will be marked on it(only English characters).
* For double-headed power plug. This makes your test more quick.

Technical parameter:
Polarity test: Test E, L, N wires in sequence.
Insulation test high-volt: DC 500V ± 10%.
Insulation resistance: 2, 7, 20, 50, 100MΩ (can be made to order).
Inner high-volt: 0~5KV ± 5% (adjustable).
Outer high-volt: 0~5KV ± 5% (adjustable).
Leakage current: 0.5, 1, 3, 5, 10mA(can be made to order).
Rated power: 500VA.
Cylinder power: Compressed air with 0.4 to 0.6Mpa.
Dimensions: 750mm W, 540mm D, 520mm H.
Power source: AC 220V± 10%, 50Hz.
Weight: 40 kg, approximate.

NOTICE:
1. Inner high-volt applies between L, N, E wires, and the outer high-volt applies between L, N, E wires and jacket.
2. Both 3-core and 2-core power plug can be tested by this machine.