Specification(@20 °C)
|
NE-300/12-230
|
NE-300/24-230
|
NE-300/12-120
|
NE-300/24-120
|
Output Continuous Max. Power
|
300W
|
|||
Output Surge Power
|
600W
|
|||
Converting Max. Efficiency
|
>88%
|
>92%
|
>88%
|
>92%
|
Normal Input Voltage
|
DC12V
|
DC24V
|
DC12V
|
DC24V
|
Input Voltage Range
|
DC10~15V
|
DC20~30V
|
DC10~15V
|
DC20~30V
|
Output Voltage
|
AC230±5%
|
AC120±5%
|
||
Output Frequency
|
50Hz±2%
|
60Hz±2%
|
||
Output Wave Form
|
Modified Sine Wave
|
|||
No load Current(Average)
|
<0.12A
|
<0.10A
|
<0.12A
|
<0.10A
|
Input Low-Voltage Alarm Voltage
|
10.5±0.5V
|
21±0.5V
|
10.5±0.5V
|
21±0.5V
|
Input Under-voltage Cut Off Voltage
|
10±0.5V
|
20±0.5V
|
10±0.5V
|
20±0.5V
|
Input Over-voltage
Cut Off Voltage
|
15±0.5V
|
30±0.5V
|
15±0.5V
|
30±0.5V
|
*: Measuring output voltage, please use the RMS Meter, or there will be errors between measurement and actual value. No load current is measured under the normal input voltage.
G.W.:1.2kg
Size: 200 mm *122mm *52 mm