Detailed Product Description
Our patent energy saving lamp:
-Reduce Energy Consumption to 60%
-Install Easy
-Life span is 15000+ hr
-Environmental Saving
-Reduce Energy Consumption to 60%
-Install Easy
-Life span is 15000+ hr
-Environmental Saving
Energy Saving Same as LED!!
Only 10% Price of LED~~
15,000hr Life Span
T5/T8 energy saving lamp have Brighten, Soft and General type to fit different places, such as supermarket, hospital, bank and factory.
Patent self-ballast energy saving lamp is electronic ballast design, perfectly integrated with the light tube.
General type without neither reflector frosted glass, can render the objects the real color naturally.
(Brighten type with Nano reflector to enhance the luminosity obviously.)
T5 inside T8, the outside tube can protect the explosive and the water, energy saving up to 60%.
|
Model
|
Item
|
|||
|
Voltage(V), Frequency(Hz)
|
AC140V-260V, 50Hz
|
|||
|
Tube Type
|
T5 in T10
|
|||
|
Length
|
600mm
|
900mm
|
1200mm
|
1500mm
|
|
2’
|
3’
|
4’
|
5’
|
|
|
Watts
|
12W
|
16W
|
22W
|
30W
|
|
Convince of T8
|
20W
|
30W
|
40W
|
58W
|
|
Power Factor (λ)
|
0.95+
|
|||
|
Color Temperature
|
6500K
|
4000K
|
3000K
|
2700K
|
|
Average Life Hours
|
12,000+hrs
|
|||
|
Current (A)
|
0.11
|
|||
|
Luminous Efficient (Lm/W)
|
95Lm/W
|
|||
|
Lumens (Lm)
|
2100Lm (for 22W)
|
|||
|
CRI
|
Ra:85
|
|||
|
Cap Type
|
G13
|
|||
The energy-saving “TUBE-IN-TUBE” light correlation information:
A.Reduce Energy Consumption: reduce up to 60% of energy consumption, comparing to conventional T8; reduce up to 50% of heat generation, comparing to conventional T8, which will reduce the work load of air-conditioning.
B.Replace of T8 Easily: only need to remove the starter and T8, then insert FSZL light.
C.Enhance Luminosity: incorporates new generation of tri-phosphor and embedded reflective material to enhance 50% comparing to conventional T8.
D.Prolonged Life Cycle: prolonged light life of 12,000+ operating hours reduces maintenance cost, meanwhile we warranty time last 12 months.
E.Increase Efficiency: a high power factor of 0.95 avoids demand penalty from electricity company.
F.Working Safely: “Tube-in-Tube” design keep our florescent tube under modulated working environment to maximize performance and product life.
G.Environmental Saving:
1) Healthier life: higher flicker frequency to reduce eye stress and migraine;
2) CO2 reduction: each FSZL tube can save 0.022kW when compared with a T8, which saves 192.72kWh per year, or 156.75lbs of burning coal.