1. Application
GSG1-100 range separated switch (shortened form separated switch) mainly use in the electricity-distribution networks as the master switch of the power supply to break or make the circuits with loads. When it in switching-on status, it can take the normal working current as well as the specified faulty current within the specified time to ensure the power continuousness of the networks and circuits; while it is in the switching-off status, it can provide the reliable insulating gap to make the electricity-consumer equipment as well as the circuit to be isolated with the power supply and to prevent the electricity-consumer equipments from being damaged due to the over voltage and also ensure the safety maintenance working for the electricity-consumer equipment.
2. Feature
GSG1-100 range separated switch (shortened form separated switch) mainly use in the electricity-distribution networks as the master switch of the power supply to break or make the circuits with loads. When it in switching-on status, it can take the normal working current as well as the specified faulty current within the specified time to ensure the power continuousness of the networks and circuits; while it is in the switching-off status, it can provide the reliable insulating gap to make the electricity-consumer equipment as well as the circuit to be isolated with the power supply and to prevent the electricity-consumer equipments from being damaged due to the over voltage and also ensure the safety maintenance working for the electricity-consumer equipment.
2. Feature
Products accord with the IEC60947.3, GB14048.3 substances
Through the CCC certification, the EU CE safety certification.3. Parameters
GSG1-100 range separated switch main technical parameters
|
item
|
parameters
|
note
|
|
type
|
GSG1-100
|
|
|
Usage classification
|
AC-22
|
|
|
Rated Insulation voltage
|
415V
|
|
|
Rated operating voltage
|
240/415V
|
|
|
Frequency
|
50/60HZ
|
|
|
Convention thermal current
|
100A
|
|
|
Rated operating current
|
32A, 63A, 100A
|
|
|
Pole
|
1, 2, 3, 4P
|
|
|
Rated Impulse Withstand voltage
|
6000V
|
|
|
Short-time with stand current
|
20le
|
Time tolerance1s
|
|
Rated short-circuit the
ability to connect
|
30le
|
Making time ≥ 0.1s
|
|
Rated ability to connect
|
3le
|
|
|
Breaking capacity of rated limit short-circuit
|
3le
|
|
|
The number of on-load operation
|
2000
|
|
|
he number of no-load operation
|
10000
|
|
|
wiring capacity
|
50mm2
|
|
4. Operating instruction
Terminal Blocks to be fastening wire, there does not allow loose, so that the wires and terminals to maintain good contact; The product is for maintenance-free type, does not allow users to open repair.