Product Main

Specifications

1.RCCB Application
GSL1 series residual current operated circuit -breaker(hereafter simply reffered to as breakers) are one of the new type of breakers which have been developed by the company using advanced design and manufacturing technology.The rated insulation voltage of the breakers is 800V,suitable for turn-on of turn-off not frequently in the circuit of AC50Hz, rated working voltage 400V and rated working  current  up  to  630A.  The  breakers equipment against damage may caused by long -term existed earth fault, which can't be examined by the over-current protection device.
The breakers have the following characteristics: compact size,high breaking capacity, short arc -over distance and shakeproof,etc.
The breakerscould be installed vertically(upring) or horizontally(transverse).
The breakers can't be fed inversely,only allowing 1,3,5 connect with power supply wires,2,4,6  connect wth load wires.
The breakers are applicable to isdation, its corr- esponding symbol is shown as“        The breakers comply with the demands of the following   standards; 
 IEC60947-1 and GB14048.1General
 IEC60947-2 and GB14048.2Low voltage breakers and appendix B MCCB with residual   current protection
IEC60947-4-1 and GB14048.4Electro-mechanical contactors and motor starters
The breakers acquired the "CCC" certificates  approved by CQC (China Quality Centification  Center).
2.Matters needing attention
All the performance of the breaker have been set  by the company, and it could not be adjusted  arbitrarily in use.
The rated residual working current and residual current working time (undelay and delay) of the breakers can be adjusted by the users according   to actual needs (operated by professionals).
As the main circuit is energized,For the rated residual working time of undelayed of the breaker, Press the button of simulating residual current working test should release immediately. For the delayed breaker,only while,press the test  button and remain the adjusted  delay time value, the breaker could release.
After the breaker released due to creepage,the creepage indicating button on the panel should  be out-protrude.
The breaker with creepage alarm unit module must reset the return button when creepage alarmed,and the creepage protection module of the breaker can work as normal.
3, ORDERING NOTICE
Users should sure of their detailed acquaintance of the products' technological materials and make order by the erdering notice in terms of future applicable situations of the circuit breakers.  
The campany would configure by "Factory's setting values of residual current protection"if users had no requirements of  protection parameters of
Residual current when makingorder.  
Four poles breakers for the share wire of three -phase four-wire 400V/230V or single phase and Three-phase