Product Main

Specifications

Two Layers of Steel Wire Armored Outdoor Fiber Cable (GYTA33)

We can supply various kinds of fiber optic cable, such as GYXTW(S)(Y), GYTS(GYTA), GYXTC8(GYTC8S), GYFTY(GYTY), GYTA(S)(Y)53, ADSS, GJFJV, etc. We can also provide OEM service and welcome customer's design.
 
Product characteristic:

1. With good crush resistance and moisture-performance Reasonable structure design and precise control for over length
2. Ensuring excellent characteristics of mechanical tensile strain and environment temperature
3. High strength loose tube material with good performance of hydrolysis resistant, specially tube filling compound ensure a critical protection of fiber
 
Application:

Used for cable can be used in Telecommunication, Video, Data Transmission, Data Transmission, CATTV, Long Distance, Backbone, Local Area Network.
Other Outdoor Optical Fiber Cable types:
GYTA33
GYTA53
GYTA
GYDTA
GYTS
GYTY53
GYTC8S
GYXTC8S
GYTC8Y
GYFTC8Y
GYXTW
GYDXTW

Technology parameter:

GYSTA33 outdoor fiber optical Cable
 
Userange It can work in river for communication
General properties unit Nominal value
Fiber Count (G652D) MM   2-144fibers
Loose tube   6fiber per tube)
Fillers compound   3 fillers
Core wrapping   petroleum jelly
Intermediate strength member   Armid yarn
Center strength member   Steel wire
Moisture Barier   polymer coated Aliminum tape with 28mm thinkness,
Steel armorred   12*1.8mm steel wire
Ripcord   1pcs under the sheath
Inner jecket mm 2.0 (Water blocking layer)
Outer jecket mm 2.5± 0.1(Water blocking layer)
Cable overal Dia. mm Mm 19.9± 1.0mm
Cable Net weight Kg/km 321kg-825kg
Delivery Length   2000± 5%
Durm size( steel +wooden):   1.6m*1.0m
Gross weigth, Kg/drum   1662kg/drum
Tensile Strength at Operatio N 10000
Tensile strength at Installation
 
N 20000
Working conditions
Temperature range: Transport and storage: -40 deg C to +70deg c
Installation: -10deg C to +60deg C
Operation: -40 degC to+70 degC
Minimal bending radius:
Installation: 20XOD
Work condition: 10xOD
Testing item standard Specified Value AcceptanceCriteria
Temperature Cycling IEC 794 1 F1 - 40  ~+70 ≤ 0.1db/Km
 
Pulling Resistance
 
  I EC 794 1 E1 20000N      ≤ 0.1db/Km
Crush resistance I EC 794 1 E4 5000N/100mm  No Fiber Breakage
Water
Penetraction
I EC 794 1 F5 Water coloum for 24H No water leakage
Life times 30 years