Stackable power inverter can be used in parallel as well as a single unit. The number of stackable power inverters in one paraller system can be composed freely in the range of 10 piece. At this way, the largest output power can be very larg after stacking. For example, if you use 10 units NE-2500P in paraller, the total output power can reach to 25,000W. This is the special technique of ours.
Specification(@20 °C)
|
NE-2000P/12-230
|
NE-2000P/24-230
|
NE-2000P/48-230
|
NE-2000P/12-120
|
NE-2000P/24-120
|
NE-2000P/48-120
|
Output Continuous Max. Power
|
2000W
|
|||||
Output Surge Power
|
4000W
|
|||||
Converting Max. Efficiency
|
>88%
|
>90%
|
>92%
|
>88%
|
>90%
|
>92%
|
Normal Input Voltage
|
DC12V
|
DC24V
|
DC48V
|
DC12V
|
DC24V
|
DC48V
|
Input Voltage Range
|
DC10~15V
|
DC20~30V
|
DC40~60V
|
DC10~15V
|
DC20~30V
|
DC40~60V
|
Output Voltage
|
AC230±5%
|
AC120±5%
|
||||
Output Frequency
|
50Hz
|
60Hz
|
||||
Output Wave Form
|
Modified Sine Wave
|
|||||
No load Current(Average)
|
<0.20A
|
<0.15A
|
<0.12A
|
<0.20A
|
<0.15A
|
<0.12A
|
Input Low-Voltage Alarm Voltage
|
10.5±0.5V
|
21±0.5V
|
42±1V
|
10.5±0.5V
|
21±0.5V
|
42±1V
|
Input Under-voltage
Cut Off Voltage
|
10±0.5V
|
20±0.5V
|
40±1V
|
10±0.5V
|
20±0.5V
|
40±1V
|
Input Over-voltage
Cut Off Voltage
|
15±0.5V
|
30±0.5V
|
60±1V
|
15±0.5V
|
30±0.5V
|
60±1V
|
*: Measuring output voltage, please use the RMS Meter, or there will be errors between measurement and actual value. No load current is measured under the normal input voltage.