Fuel Consumption Flow Meter (rotary piston type)
V4 / V4 OEM / V4R data: V8 flow sensor data :
size: DN 4 mm connection:G1/4" size: DN 8 mm. connection:G1/2"
pressure:PN 32 bar. repeatability:± 0.2%. pressure:PN 32 bar. repeatability:± 0.2%
range:1~80L/H. . normal rate:50L/H range:4~200L/H normal rate:135L/H
Max.error: 2.0~80 L/H: ± 1% Max.error: 4~200 L/H: ± 1%
1~2 L/H: +1/-2 %
Pipe fitting option: Female screw M14*1.5
V4 Flowmeter: with mechanical counter, without pulse output.
V4OEM flow sensor: Max.load: 180 Vdc, 1.25A, Pulse value: 0.005 Litre/pulse
V4R flow meter: with mechanical counter and pulse output, Max.load: 100Vdc / 0.5A, 0.005 Litre/pulse
LCD totalizer OP1(remote display, total volume)
The totalizer used low-power-consumption processor and special LCD driver chip. Inner li-battery can support the totalizer for 6 years. The totalizer used 8-digit LCD indicator. It’s specially equipped with V4 OEM flow sensor.
Technical data:
1.8-digit LCD indicator (top total flow: 999999.99 liters)
2.Digit high 6mm
3.Li-battery inside, it can works for 6 years without outside power supply
4.Data will be kept in memory when battery does not works.
5.Totalizer can be installed separately with flow sensor. It’s easy to read data.
6.Total volume can not be reset
7.High revolution, the last digit is 0.01L
LCD totalizer OP2(remote display, total volume)
Technical data:
1. It can display batch volume (can be reset), and Total volume (can not be reset)
2. For other technical data, OP2 is as same as OP1