Product Main

Specifications

1. Superior ability to adapt electric networks
220V±25% of wide input voltage range makes UPS work normally in poor power environment, it reduces the battery discharging opportunity and extends battery life.
 
2. Cold start
Battery pack can be activated directly by UPS in the absence of electric power; users' emergency needs can be fulfilled.
 
3. Super load compatibility
Strong carrying capacity, load compatibility, can be applied to different types of load, meet various application needs.
 
4. Perfect protection
Protection of input/output over-voltage, low-voltage, output over-current, short-circuit, battery low-voltage, battery over-charge, power device's over temperature, ensuring the stability of system.
 
5. No transfer time
Built-in static bypass electronic switch, if UPS is under protection or breakdown, the power supply will be switched to bypass without interruption. It especially suits equipments that have strict time requirements of power-fail. 
 
6. Perfect battery management
Offer the most reasonable charging current according to battery parameter curve, set the best charging current according to battery capacity, improve battery efficiency, extend battery lifespan.
 
7. High-current charger
Built-in high-current charger can be applied to occasions with frequent power failures and long time power disconnection.
 
8. Large screen LCD+LED display, free human-machine communication.
UPS working state can be judged by LED, UPS parameters such as input/output and battery can be observed by LCD.
 
9. Intelligent monitoring function
Communicate with computer through RS232 interface and UPS intelligent monitoring software, display UPS working parameters on screen. UPS can also achieve network monitor through the installation of SNMP card, and can be observed and managed UPS working parameters remotely through the network.
 
10. Series connection hot backup and parallel connection redundancy can be achieved.
 

Model
CP801
CP802
CP803
CP804
CP806
CP808
CP810
CP815
CP820
Capacity
1KVA
2KVA
3KVA
4KVA
6KVA
8KVA
10KVA
15KVA
20KVA
Operating principle
 
Pure sine wave dual conversion on-line
AC input
Phase
single-phase L+N+G
Voltage
220V±25%
Frequency
50HZ±10%
 
DC
 
Rated DC voltage
48Vdc
192Vdc
floating voltage
54.5Vdc
218Vdc
 Cut-off voltage
42Vdc
168Vdc
Charging time
charge to 90% in 8 hours
 
AC output
Phase
single-phase L, N+G
Voltage
220Vac±2%( stable load), 220Vac±5%(fluctuant load))
Frequency
50Hz±0.5%( On battery)
Power factor
0.8
Wave-form
Sine wave
Total voltage harmonics distortion
linear load <3%, non-linear load <5%
Output voltage transient characteristic
±5%( Load abrupt change From 0 to 100%)
Transient response time
<20ms
Crest factor
3:1
Overload protection
>125%, 1min:>150%, 200ms
 
System spec
Full load efficiency
≥90%
Transfer time
0ms
Protection
Overload, over charge and over discharge: out the range of voltage and frequency, over current, short circiut, over temperature ect.
Display
 LCD and LED indicator
Communication
Rs232 interace and SNMP card(optional)
Environment temperature
-5~40℃
Relative ambient humidity
20~95% (Non-condensing)
Altitude
<1500m: 1% rated capacity decrease against rised 100m
 Safety rate
IP21
Cooling method
forced air-cooling with temperature control
Noise (dB)
<55dB
<60dB
Dimension (W*D*H)mm
200×480×490
210×612×540
240×540×680
330×640×885
550×450×1080
/380×681×935
Weight (Kg)
39
66
74
65
67
85
110
125
200