AR-1057 / 1058 / 1068 / 1069 Features
◆Din-Rai
◆Operating Temperatures : -20 ℃~ +75 ℃
◆Input Power : +10VDC ~ +30VDC
◆Isolation P rotection ; 3000VDC
◆Protocol : Modbus-RTU / Modbus-ASCII
◆Output LED Indicator
AR-1057 / 1058 / 1068 / 1069 Introduction
The AR series is a family of network data acquisition and control modules that support Modbus RTU and Modbus ASCII protocols. AR series can easily communicate with most popular SCADA/ HMI software and PLC
|
AR-1057 / 1058 / 1068 / 1069 Pin Assignments
|
|
Item
|
AR-1057/1058
|
AR-1068/1069
|
Item
|
AR-1057/1058
|
AR-1068
|
AR-1069
|
|
1
|
DO 7~9COM
|
RL5 NO
|
14
|
DO0~2 COM
|
RL0 NO
|
RL0 NO
|
|
2
|
DO 7
|
RL5 COM
|
15
|
DO 0
|
RL0 COM
|
RL0 COM
|
|
3
|
DO 8
|
RL5 NC
|
16
|
DO 1
|
RL0 NC
|
NC
|
|
4
|
DO 9
|
RL6 NO
|
17
|
DO 2
|
RL1 NO
|
RL1 NO
|
|
5
|
DO 7~9 GND
|
RL16 COM
|
18
|
DO 0~2 GND
|
RL1 COM
|
RL1 COM
|
|
6
|
DO 10~11 COM
|
RL6 NC
|
19
|
DO3~4 COM
|
RL1 NC
|
NC
|
|
7
|
DO 10
|
RL7 NO
|
20
|
DO 3
|
RL2 NO
|
RL2 NO
|
|
8
|
DO 11
|
RL7 COM
|
21
|
DO 4
|
RL2 COM
|
RL2 COM
|
|
9
|
DO 10~11 GND
|
RL7 NC
|
22
|
DO 3~4 GND
|
RL2 NC
|
RL3 NO
|
|
10
|
(Y)DATA+
|
(Y)DATA+
|
23
|
DO 5~6 COM
|
RL3 COM
|
RL3 COM
|
|
11
|
(G)DATA-
|
(G)DATA-
|
24
|
DO 5
|
RL3 NO
|
NC
|
|
12
|
(R)+VS
|
(R)+VS
|
25
|
DO 6
|
RL4 COM
|
RL4 NO
|
|
13
|
(B)GND
|
(B)GND
|
26
|
DO 5~6 GND
|
RL4 NO
|
RL4 COM
|
|
|
AR-1057 / 1058 / 1068 / 1069 Specifications
|
|
Interface
|
|
|
AR 1057
|
AR1058
|
AR1068
|
AR1069
|
|
Output Channels
|
12
|
12
|
8
|
8
|
|
Connectors
|
2X plug-in terminal blocks(#14~28AWG)
|
|
Power Consumption
|
0.96W@24VDC
|
0.96W@24VDC
|
1.68W@24VDC
|
2.88W@24VDC
|
|
Supported Protocols
|
Modbus-RTU/Modbus-ASCII
|
|
Output Type
|
Souce
|
Sink
|
Relay
|
Power Relay
|
|
Output Isolation Voltage
|
3000VDC
|
|
LED Indicators
|
Yes
|
|
Output Rating(max)
|
10-35VDC/1A
|
40VDC/200mA(Open Collector)
|
0.5A@120VDC/1A@30V
|
5A@250V/5A@30VDC
|
|
Chanel Type
|
Digital
|
Digital
|
6X from C/2X from A
|
3X from C/5X from A
|
|
Output off Time
|
<1ms
|
<1ms
|
<8ms
|
<8ms
|
|
Output on Time
|
<1ms
|
<1ms
|
<7ms
|
<7ms
|
|
Power on Set Value
|
Yes(Power on output value)
|
|
Communication fail set value
|
Yes(Force the DO channels to safety status when communication in time-out and over pre-defined period)
|
|
Casing
|
|
Mechanical
|
Plastic
|
|
Flammability
|
Fire Retardant Materials
|
|
Dimensions(W*H*D)
|
118.2mm*76.4mm*38.5mm
|
|
Installation
|
DIN-Rail
|
|
Environment
|
|
Operating Temperature
|
-20 ℃~ +75 ℃
|
|
Storage Temperature
|
-25 ℃~ +80 ℃
|
|
Humidity
|
10-90%RH, no-condensing
|
|