DDM100TC Three Phase Four Wire DIN-Rail Power Meter, LCD display.
FUNCTIONS AND FEATURES:
1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Seven poles width.
3. LCD 6+1 or 5+2 display without backlighting; May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
4. Standard configuration one port of pulse output passive (polarity), may select increase a distant port of pulse output passive (nonpolarity), complying with standard IEC62053-31 and DIN 43864.
5. LED indicates phase-line, impulse, reverse, etc.
6. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
7. Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current, complying with standard IEC62053-21, IEC62052-11.
8. May select two components measure three phase three wire active energy or two phase three wire active energy.
9. Direct connect operation or through CT or PT & CT.
10. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install; May select extended terminal cover.
FUNCTIONS AND FEATURES:
1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Seven poles width.
3. LCD 6+1 or 5+2 display without backlighting; May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
4. Standard configuration one port of pulse output passive (polarity), may select increase a distant port of pulse output passive (nonpolarity), complying with standard IEC62053-31 and DIN 43864.
5. LED indicates phase-line, impulse, reverse, etc.
6. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
7. Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current, complying with standard IEC62053-21, IEC62052-11.
8. May select two components measure three phase three wire active energy or two phase three wire active energy.
9. Direct connect operation or through CT or PT & CT.
10. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install; May select extended terminal cover.
| TECHNICAL PARAMETERS | |
| Accuracy | Class 1.0 |
| Rated voltage(VAC) | 3*57.5/110, 3*110/200, 3*220/380, 3*230/400, 3*240/415, etc. |
| Operation voltage range | Un± 20% |
| Insulation capabilities | AC voltage withstand 2kV for 1 minute; Impulse voltage withstand 6kV - 1.2/50μ s waveform |
| Rated current(A) | 1.5(6), 5(30), 10(60), 20(80), 30(100), etc. |
| Operation current range | 0.05Ib~ Imax |
| Starting current | 0.004Ib |
| Rated frequency | 50Hz or 60Hz |
| Internal power consumption | Voltage circuit ≤ 1.0W 5VA; Current circuit ≤ 1VA(Ib) |
| Impulse valence Ra | 0.5 or 1.0 Wh/imp |
| Interface | optical coupler (SO corresponding to DIN 43864) |
| Temperature Range | Normal operation temperature: -35º C--+70º C |
| Extreme operation temperature: -40º C--+75º C | |
| Storage Temperature: -45º C--+85º C | |
| Relative humidity | ≤ 85% |
| Service Life | More than 10 years |
| Dimension | 125mm x 88mm x 73mm |
| Weight | Approx 650g |
| *Please advise us if you need any different specifications, we can make according to your special requirements. | |