Product Main

Specifications

ZY6014D  Bundle Wires and Cables Flame Tester .
1.    Introduction: this device applies to evaluate suppression ability of spread of fire for bundles installed wires and cables under specified condition.
2.    Main components: testing chamber ,air source, effluent  purification apparatus, steel elevator, ignition source and so on .
3.    Main parameters :
3.1   testing chamber size: 1000±100mm (W )    × 2000±100mm(D)  × 4000±100mm(H)
3.2   entrance air flow :5000±500 L/min
3.3   ladder frame:  500±5mm(W)        800±10mm(W)
3.4   effluent  purification apparatus :smoke and moist filter which filtered with water , smoke effluent apparatus attached a fan and switch in order to control air flow speed  , spray apparatus is to supply water for special filter materials to filter smoke and moist.
3.5   Installation condition :room temperature 25±5°c , no glare sunshine, position for smoke effluent : 5m ( H )   * 5.5m(D) * 4m(W)

Bundle Wires and Cables Flame Tester