Detailed Product Description
XLPE insulated PVC sheath power cable:
1. CCC, CE certificate and IEC Standard
2. Prompt Delivery
3. Favorable Offer
1. CCC, CE certificate and IEC Standard
2. Prompt Delivery
3. Favorable Offer
XLPE insulated PVC sheath power cable
-Conductor:
Solid or stranded copper
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Circuit Identification:
The insulation shall be red, black
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black)
-Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specifications:
IEC 60502-1.
Installation
This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
1. The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, din standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 mm2 (copper or aluminum conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
2. Brief Construction:
Single core or multi-core
Copper or aluminum conductor
XLPE insulation
-Conductor:
Solid or stranded copper
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Circuit Identification:
The insulation shall be red, black
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black)
-Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specifications:
IEC 60502-1.
Installation
This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
1. The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, din standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 mm2 (copper or aluminum conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
2. Brief Construction:
Single core or multi-core
Copper or aluminum conductor
XLPE insulation
XLPE power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat-aging and environmental stress. Its structure is simple. the long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
Our XLPE cables can be produced according to our works' specification which is equivalent IEC 502-1997, and its some indexes are superior to 502-1997.
We can design and manufacture special XLPE cable according to the other standards.
Our XLPE cables can be produced according to our works' specification which is equivalent IEC 502-1997, and its some indexes are superior to 502-1997.
We can design and manufacture special XLPE cable according to the other standards.
CABLE 'S TYPE AND MAIN APPLICATION
|
|||
TYPE
|
Description
|
Main Application
|
|
CU CORE
|
AI CORE
|
||
YJV or YJY
|
YJLV or YJLY
|
XLPE insulated, PVC or PE sheath power cable
|
For laying indoor, tunnel, canal and underground. unable to bear external mechanical forces ,but bear the traction force during laid
|
YJV22orYJY23
|
YJLV22orYJLY23
|
XLPE insulated, steel tape armored, PVC or PE sheath power cable
|
For laying indoor, tunnel, canal and underground. able to bear external mechanical forces ,but unable to bear large pulling force
|
YLV32orYJV33
|
YJLVorYJLY33
|
XLPE insulated fine steel wire armored, PVC or PE sheath power cable
|
For laying in shaft, water underground will large difference of level. able to bear external mechanical force and moderate pulling force
|
YJV42orYJV43
|
YJLV42orYJLV43
|
XLPE insulated, thick steel wire armored, PVC or PE sheath power cable
|
For laying in water and seabed, able to bear positive pressure and pulling force
|