| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | Yitai |
| Model Number: | APC-2000 |
| Output Power: | 1 - 200KW |
| Output Type: | Single |
| Size: | 580*315*300mm |
| Weight: | 22KG |
| Input Voltage: | 12/24/48V |
| Output Voltage: | 220V/110V |
| Type: | DC/AC Inverters |
| Output Frequency: | 50/60HZ |
| Output Current: |
Quick Details
Specifications
| Electrical Specvifications | ||||||||
| Model | APC-1000 |
APC -1500 |
APC-2000 | APC- 3000 | APC-4000 | APC-5000 | APC- 6000 | |
| Inverter Output | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
| Surge Rating(20s) | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | |
| Capable of Starting Electric Motor | 1HP | 1.5HP | 2HP | 3HP | 4HP | 5HP | 6HP | |
| Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||||||
| Nominal Efficiency | >88%(Peak) | |||||||
| Line Mode Efficiency | >95% | |||||||
| Power Factor | 0.9-1.0 | |||||||
| Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||||||
| Output Voltage Regulation | ±10% RMS | |||||||
| Output Frequency | 50/60Hz ± 0.3Hz | |||||||
| Short Circuit Protection | Yes, Current Limit Function (Fault after 1sec) | |||||||
| Typical transfer Time | 10ms(Max) | |||||||
| THD | < 10% | |||||||
| DC Input | Nominal Input Voltage | 12.0Vdc | ||||||
| ( *2 for 24Vdc, *4 for 48Vdc) | ||||||||
| Minimum Start Voltage | 10.0Vdc | |||||||
| Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||||||
| Low Battery Trip | 10.0Vdc / 10.5Vdc | |||||||
| High Voltage Alarm & Fault | 16.0Vdc | |||||||
| High DC Input Recovery | 15.5Vdc | |||||||
| Low Battery voltage recover | 13.0Vdc | |||||||
| Idle Consumption-Search Mode | < 25 W when Power Saver On | |||||||
| Charge | Input Voltage Range |
Wide: 90~135VAC / 164~243VAC; Narraw: 100~135VAC / 194~243VAC; |
||||||
| Output Voltage | Depends on battery type | |||||||
| Charger Breaker Rating | 10A | 10A | 10A | 20A | 20A | 30A | 30A | |
| Max Charge Rate | 35A / 70-90A Max (Charger Current Control) | |||||||
| Over Charge Protection Shutdown | 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) | |||||||
|
Charger curve(4 stage constant current) 4 step digital controlled progressive charge |
Battery types ( *2 for 24Vdc, *4 for 48Vdc) | |||||||
| Battery type | Fast Vdc | Float Vdc | ||||||
| Gel U.S.A | 14.0 | 13.7 | ||||||
| A.G.M 1 | 14.1 | 13.4 | ||||||
| A.G.M 2 | 14.6 | 13.7 | ||||||
| Sealed Lead Acid | 14.4 | 13.6 | ||||||
| Gel Euro | 14.4 | 13.8 | ||||||
| Open Lead Acid | 14.8 | 13.3 | ||||||
| Calcium | 15.1 | 13.6 | ||||||
| De-sulphation | 15.5 for 4hrs | |||||||
| Remote Control | Yes. Optional | |||||||
| Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||
| Nominal Voltage | 120Vac | 230Vac | ||||||
| Low Voltage Trip | 80V/90V±4% | 184V/154V±4% | ||||||
| Low Voltage re engage | 90V/100V±4% | 194V/164V±4% | ||||||
| High Voltage Trip | 140V±4% | 253V±4% | ||||||
| High Voltage re engage | 135V±4% | 243V±4% | ||||||
| Max Input AC Voltage | 150VAC | 270VAC | ||||||
| Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||
| Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||
| High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||
| Overload protection | Circuit breaker | |||||||
| Output Short circuit protection | Circuit breaker | |||||||
| Bypass breaker rating | 10A | 15A | 20A | 30A | 30A | 40A | 40A | |
| Transfer switch rating | 30amp for UL & TUV | 40amp for UL | ||||||
| Max bypass current | 30amp | 40amp | ||||||
| Mechanical Specification | Mounting | Wall mount | ||||||
| Inverter Dimensions(L*W*H) | 382*218*179mm | 442*218*179mm | 598*218*179mm | |||||
| Inverter Weight | 16KG | 17KG | 20KG | 24KG | 35KG | 45KG | 45KG | |
| Shipping Dimensions(L*W*H) | 520*315*300mm | 580*315*300mm | 740*315*300mm | |||||
| Shipping Weight | 18KG | 19KG | 22KG | 26KG | 37KG | 47KG | 47KG | |
| Display | Status LEDs / Status LEDs+LCD | |||||||
| Standard Warranty | 1 Year | |||||||