Standard 40μ m filter element can be replaced by a 5μ m filter element easily for special application.
The LR maintains operating pressure when pressure oscillation between imputing pressure and compressor air
|
Size
|
MINI
|
MIDI
|
MAXI
|
||||||||
|
Medium
|
Compressed air
|
||||||||||
|
Features of structure
|
Sintered filter with water separator;
|
||||||||||
|
Mounting Type
|
Pipe mounting or foot mounting
|
||||||||||
|
Assembly position
|
Vertical ±5°
|
||||||||||
|
Connection
|
G1/8
|
G1/4
|
G3/8
|
G3/8
|
G1/2
|
G3/4
|
G3/4
|
G1
|
|||
|
Standard nominal
flow rate
|
LFR-…(-A)
|
700
|
1000
|
1200
|
200
|
2600
|
2600
|
7000
|
8000
|
||
|
LFR-…-7-(A)
|
800
|
1300
|
1500
|
2500
|
2800
|
2800
|
8500
|
8700
|
|||
|
LFR-…-M5-(-A)
|
600
|
850
|
1050
|
1700
|
1800
|
2100
|
6500
|
7200
|
|||
|
Primary pressure
|
Manual
condensate drain
|
1~16bar
|
|||||||||
|
Automatic
condensate drain
|
1.5~12 bar
|
||||||||||
|
Grade of filtration
|
40μm / 5μm
|
||||||||||
|
Capacity of condensate fluid
|
22ml
|
43ml
|
80ml
|
||||||||
|
Temperature range
|
0~60°C
|
||||||||||
|
Materials information
|
Housing: Zinc die-casting;
Filter bowl and oil bowl: PC;
Metal bowl guard: aluminium alloy
Sealing: NBR
|
||||||||||