This range of water meter is used to measure the total quantity of cold(hot) potable water which consumed in household or a resident unit, passing through the pipeline.

Compliance with standard: ISO 4064 Class B

Feature:
•Dry-dial, magnetic drive, Resistance to exterior magnet interference
•Single-jet
•Selected high quality materials for steady&reliable characteristic
•Vacuum sealed register ensures the dial kept free from fog and keep the reading clear in a long term service
•Measuring accuracy conform to ISO 4064 class B Standard
•Inner or outer adjusting device for option
•Small in size and light in weight

MAIN TECHNICAL DATA
Meter size
Dia DN (mm)
Class
Qs Overload Flow
Qp Nominal Flow
Qt Transitional Flow
Qmin Min Flow
Min Reading Lectura
Max Reading Lectura
m3/h
1/h
m3
13
A
3
1.5
150
60
0.0001
99999
B
120
30
20
A
5
1.8
250
100
0.0001
99999
B
200
50
25
A
7
3.5
350
140
0.0001
99999
B
280
70

INDICATING ERROR

At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to







DIMENSIONS AND WEIGHT
Meter size
Dia DN (mm)
L
length
B
Width
H
Height
Connecting Thread
D
Weight
kg
mm
13 110 80 80 G3/4"B 0.7
20 130 80 80 G1"B 0.95
25 160 80 93 G13/4"B 1.4

Working condition:
Water temperature:≤50°C for cold water meter
Water temperature:≤90°C for hot water meter
Working pressure:≤1Mpa