PD319 series motor protectors are inplicated to AC 380V and AC 660V low voltage system,as new intelligent integrated device that protect and monitor low-volt asynchronous motor and increased-safety motor.Besides function of motor protecting,they can provide information that the device running and tripping,so avoid of errors caused by overloading,stop slewing,breaking phase,the three phase unbalance,creepage.They are used to eletrical power,landification,light industry,coal,paper industry,steel industry,textile industry,and so on..
Standards:GB3836.3-2000 GB14048.4-2003 IE255-5,
IEC255-22
PD319 series motor protectors are inplicated to AC
|
|
|
Technical Data
|
Rated Voltage:AC380V,AC660V
Rated Current:0.5-800V
Rated Working Frequency:50Hz
Working Temperature:-20~60 centigrade
Storing Temperature:-25~70 centigrade
Relative Humidity:less than 90%
Attitude:not higher than 2500 meters
Air Condition:no medium that can cause explosion,no corrosive metal and electric dust.
Installed in place no strong striked and storm
|
Relay output
|
Tripping relay J1
|
1 nomal open and closed transfer contact
|
Programmable relay J1
|
1 nomal open contact(such as alarm setting)
|
Output capacity
|
250VAC 5A 24VDC 5A
|
Auxiliary source
|
AC source voltage
|
AC 220V AC380V±15%
|
DC source voltage
|
DC24V DC110V±15%
|
Frequency
|
50Hz±2%
|
Consumption
|
Normal work≤3W Protector starting≤5W
|
Zero-sequence current input
|
Zero-sequence transformer LJ1
|
Hole size Φ45
|
Zero-sequence transformer LJ2
|
Hole size Φ80
|
Insulating Resistance
|
Standard
|
IEC255-5 100MΩ/500V
|
Insulating Test
|
Standard
|
IEC255-5
|
Medium strength test
|
2kV(r.m.s.),50Hz,1min
|
Attact voltage test
|
5kV(peak),1MHz,400times/s,keep on 2S
|
EMC antijam
|
Standard
|
IEC200-22
|
Common-mode interference
|
2.5kV(peak)
|
Defferential mode interferance
|
1.0kV(peak),100kHz;50times/s,keep on 2s
|
Radiation field interference frequency
|
27MHz~1000Hz;density of field:10V/m
|
Static discharge interference
|
8kV
|
Fast transient interference
|
2kV;5kHz;bipolar;keep on 1min
|
|
Current
Current rating(In)
|
Set current (le) range
|
Remarks
|
2A
|
0.5~2A
|
One time current across three phase current transformer of the protector
|
5A
|
1~5A
|
25A
|
5~25A
|
100A
|
25~100A
|
200/5A
|
80~200A
|
Additional 5 transformers across three phase current transformers in the protector 5 circles by two times
|
300/5A
|
120~300A
|
400/5A
|
160~400A
|
500/5A
|
200~500A
|
600/5A
|
240~600A
|
800/5A
|
300~800A
|
|
Main Function
|
|
|
Three Phase Four Line
|
Three Phase Three Line
|
Phase voltage
|
Ua, Ub, Uc
|
—
|
Line voltage
|
Uab, Ubc, Uca
|
Uab, Ucb
|
Current
|
Ia, Ib, Ic
|
Ia,Ic
|
Active power
|
Pa, Pb, Pc, P
|
P
|
Reactive power
|
Qa, Qb, Qc, Q
|
Q
|
|
Three Phase Four Line
|
Three Phase Three Line
|
Apparent power
|
Sa, Sb, Sc, S
|
S
|
Power factor
|
PFa, PFb, PFC, PF
|
PF
|
Voltage harmonics
|
Ua, Ub, Uc (2~31times)
|
Uab, Ucb (2~31times)
|
Current harmonics
|
Ia, Ib, Ic (2~31times )
|
Ia, Ic (2~31times)
|
Voltage unbalance degree
|
Yv
|
Current unbalance degree
|
Yi
|
Voltage component
|
Positive sequence Up, Negative sequence Un
|
Current component
|
Positive sequence Ip, Negative sequence In
|
Frequency
|
F
|
Active energy
|
+kWh, -kWh
|
Reactive energy
|
+kvarh, -kvarh
|
Time-sharing calculating
|
Peak, Shoulder, Vally, Total
|
SOE event reording
|
20 pieces SOE event recording
|
Remote surveillance input
|
2 loops of switch value input
|
Remote control output
|
2 loops of switch value output
|
Communication interface
|
1 loop of RS-485 interface, MODBUS-RTU
|
Pulse output
|
2 loops of energy pulse output
|
Referenced application
|
Electric power system, Transformer, Gen-sets low voltage system wire-in, Energy measurement, Communication and management
|
|
|