Product Main

Specifications

MPPT time & light control lamp Controller 40A/50A/60A WS- ALMPPT60  

Brand : WELLSEE
Category : Controller
Model : WS-AL MPPT60
Weight :1100G
Size : 210*125*50mm 

General Information :
This new WELLSEE Solar Controller WS-AL MPPT30 controlled solar lighting charge controller will eliminate the need for seperate charge controller, timer ,light-dimmer and light control in a 12/24v lighting system. It uses the photovoltaic array to detect day and night and will learn the length of your night in order to provide light before sunrise. Save battery and array size by setting the light to turn off in the middle of the night.
  
Configuration: 
Solar panel: the system of 12v should choose the 40 pieces connected in series, the voltage of Maximum Power Point should be above 18V, the 24V system shoule be choose the two piece of the solar panel which is above-mentioned. The wire : you’d better choose the wire which is connected the solar panel and WELLSEE Solar Controller according to 1A/mm2
 
MPPT explaination
Maximum power point tracking is a technique that solar inverters use to get the most possible power from the PV array. Any given PV module or string of modules will have a maximum power point: essentially, this defines current that the inverter should draw from the PV in order to get the most possible power (power is equal to voltage times current).
 
 Functions:
1,MPPT function 
2, Microprocessor controller pulse width modulation (PWM) charging
3, amount of light can be fixed.
4, Suitable for polytype battery.
5, Overcharge protection
6, Short circuit protection (automatic restoration)
7, Thunder protection
8,Thunder protection Reverse discharge protection
9, Reverse polarity connection protection
10, It can set up to 20 steps TM Timing Module or 10 steps segment mode.
11, LET indicator to show the working condition of charging and discharging:
l   One piece of Charge Indicator LED (mark: Charge). When it is bright, the battery is charged strongly; flickeringly means floating charge, no light means stop charging.
l   One piece of Load Indicator LED (mark: Light). When it is bright, there is output and load can work; if LED goes out, means there isn’t output and the load cannot work.
l   Battery indicator: red =under voltage   Green =full    Yellow =normal 
 
3. Technical Index: 

Model
WS-AL MPPT60 40A
WS-AL MPPT60 50A
WS-AL MPPT60 60A
system voltage
12V / 24V / 48V
Max Curry Current
40A
50A
60A
Output voltage scope
12V~40V / 24V~80V /  48V~110V
overpressure protection
17V / 34V / 68V *
HVD
13.7V / 27.4V / 54.8V *
undervoltage
10.5V-11V / 21V-22V / 42V*
temperature compensation
-3mv/°C/cell
open circuit losses
≤30mA
Light control
light control turn on + light control turn off
Light control + time control
Light control turn on/off + time control turn on/off
The step of time control
0.5 hours started,half an hour of one grade ,up to 10 hours
ambient temperature
-25°C-----+55°C
quiescent current
24mA
control mode
PWM
Max loop voltage drop
350 mV