12/24V 20A/25A/30A Solar battery controllers WS-C2430 LCD display
Brand: WELLSEE
Category: Solar Battery Controller
Model: WS-C2430
Weight: 500g
Size: 164*110*45 mm
WS-C2430 25A series battery controllers (WELLSEE solar power system controller) applies in solar photovoltaic systems, which coordinates the working of solar panels, batteries and loads. WELLSEE WS-C solar battery controllers add some protection functions, so that the entire system can be in efficient and safe operation.
WS-C2430 25A series charge controllers apply to all types of photoelectric panels and various types of batteries, MCU (Micro-Processing Controller) has PMW (Pulse Modulation Wide-frequency) 0~100% variable duty cycle process. According to the types and actual charging situation of the battery, WS-C 2430 solar controller series (solar battery controller, solar voltage controller) can provide the fast and best charging voltage and electricity from the PV panel. C30 and C60 series are equipped with advanced man-machine interactive function, so the user can adjust the charging voltage.
Functions:
1. CPU control, LCD display
1. CPU control, LCD display
2. Automatic recognition of input voltage
3. Applicable to various types of durable batteries
4. Micro processing controller Pulse Modulation Wide-frequency (PWM) charge
5. Setting the voltage of low voltage cut-off/resuming connection of the DC output of the load port
6. Temperature sensor for charging a battery in compensation
7. Protective circuit of PV from reverse-charging.
8. Overload protection
9. Overcharge protection
10. Short circuit protection
11. Temperature compensate
12. Reverse polarity connection protection
13. Converse discharge protection
14. Thunder protection
15. Low voltage protection
Technical Index:
Technical Index:
Model
|
WS-C2430 20A
|
WS-C2430 25A
|
WS-C2430 30A
|
Rated Voltage
|
12V/24V Automatic voltage recognition
|
||
Max Load current
|
20A
|
25A
|
30A
|
Input voltage range
|
12V-17V/24V-34V
|
||
Length≤1m
Charge loop drop
|
0.25V
|
||
Length≤1m
Discharge loop drop
|
0.05V
|
||
Over voltage protection
|
17V/34V (Default value, can be reset)
|
||
Full charge cut
|
13.7V/27.4V (Default value, can be reset)
|
||
Low voltage cut
|
10.5~11V/21V~22V (Default value, can be reset)
|
||
Temperature compensation
|
-3mv/°C/cell
|
||
No load loss
|
≤20mA
|
||
Max wire area
|
4mm2
|
||
Ambient temperature
|
-25°C----+55 °C
|