Features:
◆ Big screen LCD display, English graphical interface touch screen input choosing to equip outlay mouse and keyboard simple and easy for operation.
◆ The whole-new operation system, with integrated software of immunity analysis can make direct Chinese input of hospital management and patients' information.
◆ 8-channel optical fiber high speed scanning special center orientation for alisa hole leads to quick and correct measuring result.
◆ Single-board multi-item testing, even 12 kinds qualitative or measurable testing can be done simultaneously on the same board.
◆ Complete quality-control way, owning the function of LJ method X,S method and instant method and double quality-control function by multi-role can display, store print quality-control data and quality-control chart of each item
◆ Visible and flexible board collocation, freely setting of position and quantity of blank comparison standard and sample.
◆ The instruments can intelligently judge the state of blank comparison and standard according to the requirement of the program parameter.
◆ Strong database can store 500 program parameters 200 thousand testing results and more than 2 years of quality-control data and quality-control chart, and freely display and print as well.
◆ The CO value and standard curve of all items can be stored permanently and be called out and printed out momentarily.
◆ utomatic single/double wavelength examination support many kinds of qualitative or measurable analytical models.
◆ Support many kinds of built-in and outlay printers print the whole report, program report and quality-control and patient general report.
◆ With the function of all-scale query and statistics convenient for the management of sections.
◆ The intelligent resting protection function for prolonging the life-span of lamp.
◆ The alisa workstation software can be chosen to equip with as well.
Main technical:
◆ Sample form: 96 or 48 hole elisa board or strip.
◆ Calclation mode: absorbbency, cut-off qualitative calculation.single-point scahng, polyline regression, rnore-point percenrage.linear regression, index regression, log regression, power regression, double-log regression and Iog-Iogit regression.
◆ Filter: standard configuration with 4 light filters of 405, 450, 492, 630nm, can reach to 8 light filters ( or according to clients' requirement )
◆ Absorbance accuracy: ±0.01A
◆ Absorbance repetition: ≤0.5%
◆ Absorbance stabliility : ±0.005A
◆ Testing speed: 5 seconds/96 holes
◆ Linear error: ±0.5%
◆ Display: LCD
◆ Input way: touching screen and pen
◆ Interface:  serial port RS232, parallet port with printer