Product Main

Specifications

 
Equal-potential Three Phase Energy Meter Test Instrument(Split Type)
Overview:  
The RT6303E Equal-potential Three Phase Energy Meter Test Instrument is an ideal new-generation multi-position embedded energy meter test instrument. The 6303E energy meter test instrument comprises of power source, standard energy meter and error processing system which can be widely used in testing various single/three phase watt-hour meters and multifunction watt-hour meters of Grade 0.2 or lower. Among all its features, the equal-potential testing method is specifically suitable for testing such watt-hour meters of Grade 0.5 or lower where the voltage and current measurement loops cannot be separated or where the voltage and current measurement loops may be separated to improve calibration and testing efficiencies, such three phase energy meters where the voltage and current measurement loops cannot be separated during testing. One of this energy meter test instrument’s important features is that its modulation amplifier’s high output and load capacity matches the three phase active separation CT to bring you a more convenient and reliable calibration in embedded energy meters.   
Technical Parameters:  
1.    Accuracy class: 0.1
2.    Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05
3.    Three phase isolated current transformer:Accuracy class:0.01(CosΦ=0.5C/1/0.5L,0.05~120A)Primary current:3 * 0.05~120A,secondary current:3 * 0.05~120AOutput power:30VA(Max 100VA)
4.    Voltage range: 3* 57.7/100/220/380V Y/△,Output range:0~120%Resolution: 0.01% full range
5.    Current measurement range: 3* 0.05~100A(Option 200A ),Output range:0~120%Resolution: 0.01% full range
6.    Phase shift:0~360°Resolution of phase angle setting: 0.01°
7.    Frequency:45Hz~65Hz,Resolution: 0.01Hz
8.    Output waveform distortion: Both voltage and current<0.5%
9.    Output voltage, current and power stability:<0.05%(180s)
10.  Output capacity(per phase): Current:1,500VA(120A); Voltage: 400VA(16 meter testing positions)
11.  Load characteristics: Resistive, inductive and capacitive(less than 4uF)
12.  Harmonic wave output:2-21st sub-harmonic wave, content<40%;3rd, 5th and 7th sub-harmonic waves, accumulated content<40%;;Control of conduction angle (odd sub-harmonic wave);Control of wave group (sub-harmonic wave)
13.  Starting up current: Minimum 1 mA, Accuracy: 5%,Starting power: Accuracy: 5%
14.  Energy meter testing positions:16(standard);3 to 16 meter testing positions also available
15.  Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing ,Dial testing and etc
16.  Power supply: AC 3*220/380V±10%,50Hz(customer define);Max. power consumption: 5000VA(16 meter test positions) 
Dimension:  
Split Type:
16 Meter testing positions(1 rack): 2200*800*1920mm
Cabinet: 600*800*1920mm