Product Main

Specifications

Our Multifuntional Hydraulic-electromagnetic circuit breaker, the products using the latest international standards for structural design of advanced reasonable and applicable to the exchange of Pathology, 230V, 415V or 85V DC electrical system for the overload protection circuit, short-circuit protection, but also for non-frequency fan access and the breaking use, has been widely used in communications equipment, laser equipment, railway locomotive, gasoline generators and other fields.
1 Standard
     GB17701-1999 EN60934-2001

2 Rated voltage
     AC 415V 50/60HZDC 85V

3 Current ratings
    10A-50A

4 Rated short-circuit breaking capacity
    1000A O-CO-CO DC 3000A

5 Pole divided into
    Unipolar and bipolar, three poles

6 Connection mode
     Bolt -

7 Certification of 
     TUVCE

8 The use of ambient temperature 

    -40+85
 
 
9 Characteristic
 
Power categories
 
1In
1.25In
1.5In
4In
6In
AC
No action
 
10s-120s
6s-90s
0.2s-3s
0.02s-2s
DC
No action
 
2s-60s
1.8s-30s
0.15s-2s