Based on HF chain and parallel operation technology with DSP, several inverter can be parallel operated and run, simplified the design of the power station.
Ø Adopted the IPM module of 5th generation of Mitsubishi, increasing the system efficiency greatly.
Ø Self-optimizing of MPPT, increasing the efficiency of power produce of PV
Ø Adopted the technology of initiative frequency offset to detect the island, make the grid protecting safe and reliable
Ø Large screen of multiple language of LCD display.
Ø Power production and CO2 emission reduction calculation for 5
Ø Flexible output setup, suitable to various countries' local regulationSpecialized remote setting and detecting software, make the computer adjusting more intelligently
Ø Delicate machinery design and light component configuration
Ø Multi-protection design, make it more safe and reliable
Ø Electrophoresis painting and machinery design of high protection grade, suitable for install indoor and outdoor
Ø Wider range of operating temperature of -25~+50℃
Ø Plug-in connection for all DC and AC water proof connector and communication cable, easy to field wiring
|
Model
|
SM3-3KTL
|
SM3-5KTL
|
SM3-7KTL
|
SM3-10KTL
|
|
|
INPUT(DC)
|
(W)Recommended Input PV Power (W)
|
3150
|
5250
|
7350
|
10500
|
|
(V)Max.PV Open Circuit Voltage
|
270
|
270
|
315
|
270
|
|
|
(A)Max.PV Input DC Current
|
18.53
|
30.9
|
43.2
|
61.76
|
|
|
(V)PV-voltage range, MPPT
|
180~360
|
||||
|
Number of MPPT trackers/Max.number of strings (parallel)
|
1/1
|
1/2
|
1/2
|
1/3
|
|
|
OUTPUT(AC)
|
(W)Nom.AC Output Power
|
3000
|
5000
|
7000
|
10000
|
|
(A)Max.AC Output Current
|
5.45
|
9.09
|
12.72
|
18.18
|
|
|
(V±%)Nom.Grid Voltage/range
|
380/380±20% of normal grid voltage by default, adjusted to local regulation
|
||||
|
(Hz±%)Nom.AC Grid Frequency/Range
|
50±0.5Hz of normal grid frequency by default, adjusted to local regulation
|
||||
|
Factor
|
≥0.99(Rated power)
|
||||
|
Output Current THD(%)
|
<5%(Rated power)
|
||||
|
Max.Efficiency
|
97.0%
|
||||
|
Euro-Eta
|
95.5%
|
||||
|
Protection Devices
|
Over/Under Voltage Protection
|
●
|
|||
|
Over/Under Frequency Protection
|
●
|
||||
|
Non-islanding
|
●
|
||||
|
Over Current Protection
|
●
|
||||
|
AC short-circuit protection
|
●
|
||||
|
Ground Fault Monitoring
|
●
|
||||
|
All-pole Sensitive Residual-current Monitoring Unit
|
●
|
||||
|
Reverse Polarity Protection
|
●
|
||||
|
Over Load Protection
|
●
|
||||
|
General Data
|
Dimensions(H/W/D)
|
435×270×172
|
510×315×183
|
605×550×205
|
695×648×232
|
|
Weight(kg)
|
15
|
22
|
32
|
45
|
|
|
Operating temperature range
|
-25~+50℃
|
||||
|
(W)Power consumption at night
|
0.25W
|
||||
|
Noise
|
≤ 42 dB(A)
|
||||
|
Topology
|
Transformerless
|
||||
|
Cooling concept
|
Natural Cooling
|
||||
|
Installation: Indoors/Outdoors (IP65 electronics)
|
● /●
|
||||
|
Features
|
Graphic display:
|
LCD
|
|||
|
Interfaces:
|
RS485/RS232
|
||||
|
|
SFENGINEER
|
||||
|
Warranty:
|
5years
|
||||