Product Main

Specifications

Based on HF chain and parallel operation technology with DSP, several inverter can be parallel operated and run, simplified the design of the power station.
Ø Adopted the IPM  module of 5th generation of Mitsubishi, increasing the system efficiency greatly.
Ø Self-optimizing of MPPT,  increasing the efficiency of power produce of PV 
Ø Adopted the technology of initiative frequency offset to detect the island, make the grid protecting safe and reliable
Ø Large screen of multiple language of LCD display.
Ø Power production and CO2 emission reduction calculation for 5 
Ø Flexible output setup, suitable to various countries' local regulationSpecialized remote setting and detecting software, make the computer adjusting more intelligently
Ø Delicate machinery design and light component configuration
Ø Multi-protection design, make it more safe and reliable
Ø Electrophoresis painting and machinery design of high protection grade, suitable for install indoor and outdoor
Ø Wider range of operating temperature of -25~+50℃
Ø Plug-in connection for all DC and AC water proof connector and communication cable, easy to field wiring
Model
SM3-3KTL
SM3-5KTL
SM3-7KTL
SM3-10KTL
 
INPUT(DC)
(W)Recommended Input PV  Power (W)
3150
5250
7350
10500
(V)Max.PV Open Circuit Voltage
270
270
315
270
(A)Max.PV Input DC Current
18.53
30.9
43.2
61.76
(V)PV-voltage range, MPPT
180~360
Number of MPPT trackers/Max.number of strings (parallel)
1/1
1/2
1/2
1/3
 
OUTPUT(AC)
(W)Nom.AC Output Power
3000
5000
7000
10000
(A)Max.AC Output Current
5.45
9.09
12.72
18.18
(V±%)Nom.Grid Voltage/range
380/380±20% of normal grid voltage by default, adjusted to local regulation
(Hz±%)Nom.AC Grid Frequency/Range
 
50±0.5Hz of normal grid frequency by default, adjusted to local regulation
Factor
≥0.99(Rated power)
Output Current THD(%)
<5%(Rated power)
Max.Efficiency
97.0%
Euro-Eta
95.5%
Protection Devices
 
Over/Under Voltage Protection
Over/Under Frequency Protection
Non-islanding
Over Current Protection
AC short-circuit protection
Ground Fault Monitoring
All-pole Sensitive Residual-current Monitoring Unit
Reverse Polarity Protection
Over Load Protection
 
General Data
Dimensions(H/W/D)
435×270×172
510×315×183
605×550×205
695×648×232
Weight(kg)
15
22
32
45
Operating temperature range
-25~+50℃
(W)Power consumption at night
0.25W
Noise
≤ 42 dB(A)
Topology
Transformerless
Cooling concept
Natural Cooling
Installation: Indoors/Outdoors (IP65 electronics)
● /●
 
Features
Graphic display:
LCD
Interfaces:
RS485/RS232
 
SFENGINEER
Warranty:
5years