Cu/XLPE/PVC power cable to be laid underground, the cable could bear certain mechanical force
ZMS cable manufacture 3 core cable, Fire proof cable, All-Aluminum Cable (AAC cable), Flame retardant cable .
ZMS cable manufacture 6.35/11KV steel tape armored cable(STA), 6.35/11 KV steel wire armored cable (SWA), 11KV SWA cable , 12/20KV 3 core Armored cable.
ZMS cable manufacture XLPE power cable supplier, PVC power cable supplier, cable supplier, XLPE PVC cable…
ZMS cable manufacture 6.35/11kV MV cable( Medium voltage cable ),26/35kV HT cable, HT cable(High tension wires), 65/110kV EHV cable, EHV cable( Extra high voltage cable )...
we manufacture andy power cable,If you need overhead cable,For example acsr cale, aac cable, abc cable...,please visit to overhead cable site.
ZMS cable manufacture 3 core cable, Fire proof cable, All-Aluminum Cable (AAC cable), Flame retardant cable .
ZMS cable manufacture 6.35/11KV steel tape armored cable(STA), 6.35/11 KV steel wire armored cable (SWA), 11KV SWA cable , 12/20KV 3 core Armored cable.
ZMS cable manufacture XLPE power cable supplier, PVC power cable supplier, cable supplier, XLPE PVC cable…
ZMS cable manufacture 6.35/11kV MV cable( Medium voltage cable ),26/35kV HT cable, HT cable(High tension wires), 65/110kV EHV cable, EHV cable( Extra high voltage cable )...
we manufacture andy power cable,If you need overhead cable,For example acsr cale, aac cable, abc cable...,please visit to overhead cable site.
XLPE Insulated PVC Sheath Power Cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower, and also used for Subway,Power station,Factory and Mine.
It can be installed underground, in pipe, in trench or in tunnel.
XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
We can produce according to GB Standard(China Standard) which is equivalent to the standard IEC60502.We can also design and manufacture special XLPE cable according to the other standards required by the clients.
Rated Voltage,Core Numbers & Nominal Cross-section Area as following Table 1-1
|
1st class
|
0.6/1
|
1.8/3
|
3.6/6
|
6/10
|
8.7/15
|
12/20
|
18/30
|
21/35
|
|||
2nd class
|
1/1
|
3/3
|
6/6
|
8.7/10
|
12/15
|
18/20
|
-
|
26/35
|
||||
1 Core
|
Section
area(mm2)
|
1.5-800
|
25-800
|
25-800
|
25-800
|
35-800
|
50-800
|
50-800
|
50-800
|
|||
2 Core
|
Section
Area(mm2)
|
1.5-185
|
/
|
/
|
/
|
/
|
/
|
/
|
/
|
|||
3 Core
|
Section
area(mm2)
|
1.5-400
|
25-400
|
25-400
|
25-400
|
35-400
|
50-400
|
50-400
|
50-400
|
|||
4 Core
|
Section
Area(mm2)
|
2.5-400
|
25-400
|
/
|
/
|
/
|
/
|
/
|
/
|
|||
5 Core
|
Section
area(mm2)
|
2.5-400
|
25-400
|
/
|
/
|
/
|
/
|
/
|
/
|
Type, Description & Application Occasion: (Table 1-2)
Table 1-1 Type Description & Application Occasion of cable
Type
|
Description
|
Application n
|
|
Cu
|
Al
|
||
YJV
|
YJLV
|
XLPE insulation PVC sheath power cable
|
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside
|
YJY
|
YJLY
|
XLPE insulation PE sheath power cable
|
|
YJV22
|
YJLV22
|
XLPE insulation, steel tape armor, PVC sheath power cable
|
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.
|
YJV23
|
YJLV23
|
XLPE insulation, steel tape armor, PE sheath power cable
|
|
YJV62
|
YJLV62
|
XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable
|
|
YJV32
|
YJLV32
|
XLPE insulation, thin steel-wire armor, PVC sheath power cable
|
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
.
|
YJV72
|
YJLV72
|
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable
|
|
YJV42
|
YJLV42
|
XLPE insulation, thick steel-wire armor, PVC sheath power cable
|
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
|
Special
Note
|
,6272.,.
The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable.
Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability.
|