- Modern tact switch for On/off;
- Double soft-start for DC input and AC output;
- Insulation for primary and secondary;
- Steady AC output voltage at loading between 1% and 100%;
- The Start-up of 'difficult' loads, such as energy saving lamps, electric motors, pumps, television sets or switching power supplies is effortless and instant.
Function Details:
|
Model
|
FPI1200-121
|
FPI1200-241
|
FPI1200-481
|
FPI1200-122
|
FPI1200-242
|
FPI1200-482
|
|
Rated power
|
1200W
|
1200W
|
1200W
|
1200W
|
1200W
|
1200W
|
|
Peak power
|
2400W
|
2400W
|
2400W
|
2400W
|
2400W
|
2400W
|
|
DC input voltage
|
12V
|
24V
|
48V
|
12V
|
24V
|
48V
|
|
AC output voltage
|
110VAC ±2%
|
230VAC ±2%
|
||||
|
No-load current
|
1.4A
|
0.7A
|
0.35A
|
1.4A
|
0.7A
|
0.35A
|
|
AC output frequency
|
60HZ
|
50HZ
|
||||
|
USB Output
|
5V 500mA
|
|||||
|
AC output waveform
|
Pure Sine Wave
|
|||||
|
Efficiency
|
>88%
|
>90%
|
>90%
|
>90%
|
>91%
|
>91%
|
|
DC input voltage range
|
10.5-15V
|
21-30V
|
42-60V
|
10.5-15V
|
21-30V
|
42-60V
|
|
Low Voltage Alarm
|
10.5±0.3V
|
21±0.3V
|
42±0.3V
|
10.5±0.3V
|
21±0.3V
|
42±0.3V
|
|
Low Voltage Shutdown
|
10±0.3V
|
20±0.3V
|
40±0.3V
|
10±0.3V
|
20±0.3V
|
40±0.3V
|
|
Over Voltage Protection
|
15.5±0.5V
|
31±1V
|
62±2V
|
15.5±0.5V
|
31±1V
|
62±2V
|
|
Low Voltage Recovery
|
/
|
|||||
|
Over Voltage Recovery
|
/
|
|||||
|
Protective Function
|
Low/Over voltage
|
LED Red light, Buzzer
|
||||
|
Over load
|
LED Red light, automatic recovery, Buzzer
|
|||||
|
Over temperature
|
LED Red light, Buzzer
|
|||||
|
Short circuit
|
LED Red light, automatic recovery, Buzzer
|
|||||
|
Input reverse connection
|
Fuse Burn-out
|
|||||
|
Working Temp.
|
0℃-40℃
|
|||||
|
Storage Temp.
|
-30℃-70℃
|
|||||
|
Dimension
|
350*198*78mm
|
|||||
|
Weight
|
3.1KG
|
|||||