Introduction:
[Main technical parameters]
Measuring range
CO: 0~10.0 10-2(%) CO2: 0~20.0 10-2(%)
HC: 0~10000 10-6(ppm) O2: 0~25.0 10-2(%)
Oil temperature: 18℃~150℃
Speed: 100~20000rpm
Measuring range
CO: 0~10.0 10-2(%) CO2: 0~20.0 10-2(%)
HC: 0~10000 10-6(ppm) O2: 0~25.0 10-2(%)
Oil temperature: 18℃~150℃
Speed: 100~20000rpm
Repeatability error
≤±2%
≤±2%
Zero drift
CO: ±0.06 10-2(%)/4h CO2: ±0.5 10-2(%)/4h
HC: ±30 10-6(ppm)/4h
O2: ±0.5 10-2(%)/4h NO: ±30 10-6(ppm)/4h
CO: ±0.06 10-2(%)/4h CO2: ±0.5 10-2(%)/4h
HC: ±30 10-6(ppm)/4h
O2: ±0.5 10-2(%)/4h NO: ±30 10-6(ppm)/4h
Span drift
No more than indication error allowable value (4 hours)
No more than indication error allowable value (4 hours)
Indication error
CO: ±5%(Relative error, 0~10%)
CO2: ±5%(Relative error, 0~20%)
HC: ±5%(Relative error, 0~4000ppm)±10%(Relative error, 4001~10000ppm)
O2: ±5%(Relative error, 0~25%)
NO: ±5%(Relative error, 0~5000ppm)
CO: ±5%(Relative error, 0~10%)
CO2: ±5%(Relative error, 0~20%)
HC: ±5%(Relative error, 0~4000ppm)±10%(Relative error, 4001~10000ppm)
O2: ±5%(Relative error, 0~25%)
NO: ±5%(Relative error, 0~5000ppm)
Environmental conditions
oil temperature: ± 2 ℃ (relative error)
Speed: ± 1.0% (relative error)
Temperature: 0 ℃ ~ 40 ℃
Humidity: ≤ 80%
Atmospheric pressure: 60 ~ 105KPa
Power: AC 220V ± 10%; 50Hz ± 1Hz
oil temperature: ± 2 ℃ (relative error)
Speed: ± 1.0% (relative error)
Temperature: 0 ℃ ~ 40 ℃
Humidity: ≤ 80%
Atmospheric pressure: 60 ~ 105KPa
Power: AC 220V ± 10%; 50Hz ± 1Hz
Preheating time
10min
10min
Weight
15KG
15KG
Volume
610 * 500 * 330mm
610 * 500 * 330mm
Simpling Exhaust
direct sampling, the length of the sampling tube is 5m, the length of the sampling probe is 900mm
Oil temperature: temperature measurement inserts into the oil gauge hole of the engine, insert length is same with the oil gauge, blocked with rubber plug to prevent oil smoke
Wire length: 5m;
Speed: fix the folder of tachometer on the high-voltage soft-line the of gasoline engine to measure the speed.
direct sampling, the length of the sampling tube is 5m, the length of the sampling probe is 900mm
Oil temperature: temperature measurement inserts into the oil gauge hole of the engine, insert length is same with the oil gauge, blocked with rubber plug to prevent oil smoke
Wire length: 5m;
Speed: fix the folder of tachometer on the high-voltage soft-line the of gasoline engine to measure the speed.
Display Mode
High-brightness LED display Large LCD display
High-brightness LED display Large LCD display
Optional configuration
temperature, speed configuration
temperature, speed configuration
Main functions
Printer built in(temperature, speed configuration) , Communication with the computer network, 30 minutes automatically prompte to zero. Idling and dual idling two measurement methods, built-in clock module to display time, number plates can be stored 500 sets of measurements data, natural gas, liquefied petroleum gas and gasoline these three fuels to choose.
Printer built in(temperature, speed configuration) , Communication with the computer network, 30 minutes automatically prompte to zero. Idling and dual idling two measurement methods, built-in clock module to display time, number plates can be stored 500 sets of measurements data, natural gas, liquefied petroleum gas and gasoline these three fuels to choose.