Product Main

Specifications

 

The DC OUT of PV inverts to stable three phase AC supply to load with KM, and feeds the redundant to national grid.

Features
Based on HF chain and parallel operation technology with DSP, several inverter can be parallel operated and run, simplified the design of the power station.
Adopted the IPM module of 5th generation of Mitsubishi, increasing the system efficiency greatly.
Self-optimizing of MPPT, increasing the efficiency of power produce of PV system.
Adopted the software calibration with the DSP, assure the power factor of 100%.
Adopted the technology of initiative frequency offset to detect the island, make the grid protecting safe and reliable.
Large screen of multiple language of LCD display.
Power production and CO2 emission reduction calculation for 5 years
Flexible output setup, suitable to various countries' local regulation
Multiprotection design, make it more safe and reliable
Specialized remote setting and detecting software, make the computer adjusting more intelligently
Wider range of operating temperature of -25~+50º C.
 
 
 
 
Product Description:
 
 
Model
KM3-3KTL
KM3-5KTL
KM3-7KTL
KM3-10KTL
INPUT(DC)
Recommended Input PV  Power (W)
3150
5250
7350
10500
Max. PV Open Circuit Voltage
270
270
315
270
Max. PV Input DC Current
18.53
30.9
43.2
61.76
PV-voltage range, MPPT
180~360
Number of MPPT trackers/Max. number of strings (parallel)
1/1
1/2
1/2
1/3
 
Nom. AC Output Power
3000
5000
7000
10000
OUTPUT(AC)
Max. AC Output Current
5.45
9.09
12.72
18.18
 
Nom. Grid Voltage/range (V± %)
380/380± 20% of normal grid voltage by default, adjusted to local regulation
 
Nom. AC Grid Frequency/Range(Hz± %)
50± 0.5Hz of normal grid frequency by default, adjusted to local regulation
 
 
Factor
≥ 0.99(Rated power)
 
Output Current THD(%)
< 5%(Rated power)
Max. Efficiency
97.00%
Euro-Eta
95.50%
Protection Devices
Over/Under Voltage Protection
 
Over/Under Frequency Protection
 
Non-islanding
 
Over Current Protection
 
AC short-circuit protection
 
Ground Fault Monitoring
 
All-pole Sensitive Residual-current Monitoring Unit
 
DC Reverse Polarity Protection
 
Over Load Protection
 
General Data
Dimensions(H/W/D)
435× 270× 172
510× 315× 183
605× 550× 205
695× 648× 232
Weight(kg)
15
22
32
45
Operating temperature range
-25~+50º C
Power consumption at night(W)
0.25W
Noise         
≤ 42 dB(A)
Topology
Transformerless
Cooling concept
Natural Cooling
Installation: Indoors/Outdoors (IP65 electronics)
 
Features
Graphic display
LCD
Interfaces
RS485/RS232
Remote monitor software
SFENGINEER
Warranty
5years